Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Nov-Dec;24(6):535-540.
doi: 10.4103/jisp.jisp_523_19. Epub 2020 Nov 14.

Comparative evaluation of use of a diode laser and electrode application with and without two dentinal tubule occluding agents in the management of dentinal hypersensitivity - A clinical study

Affiliations

Comparative evaluation of use of a diode laser and electrode application with and without two dentinal tubule occluding agents in the management of dentinal hypersensitivity - A clinical study

Chitra Laxmikant Patil et al. J Indian Soc Periodontol. 2020 Nov-Dec.

Abstract

Background: Dentinal hypersensitivity (DH) is common problem in dentistry. Traditional agents along with alternative therapies have been researched. Aim: To study the efficacy of a diode laser (DL) and electrode application with and without hydroxyapatite (HAP) and strontium chloride (SrCl2) powder.

Materials and methods: 60 Patients with mild cervical abrasion in at least two quadrant with two teeth per quadrant were selected and randomly divided into four groups: (i) Group 1- DL versus DL with HAP (ii) Group 2 - electrode application versus electrode application with HAP (iii) Group 3 - DL versus DL with SrCl2 (iv) Group 4 - electrode application versus electrode application with SrCl2 and were subjected to tactile stimulus and air blast test and scores were recorded on verbal rating scale (VRS) and visual analogues scale (VAS) at different time for 3 months. The data was statistically evaluated by one way ANOVA and paired t test.

Results: In group 1 and 3, DL alone had a short term reduction of hypersensitivity (P = 0.001). Synergistic effect of DL and HAP (group 1) showed a prolonged reduction on both scales (P < 0.001) whereas the additive effect of SrCl2 with DL (group 3) showed statistically significant reduction on both scales at all time (p<0.001). In group 2 there is insignificant difference on both scales at all time (P > 0.05) however group 4 showed significant reduction only in VAS score (p>0.05).

Conclusion: DL alone had a short lived effect however with adjunctive sustained results were obtained whereas electrode application was neither beneficial nor did cause any adverse effect.

Keywords: Dentinal hypersensitivity; diode laser; electrosurgical unit; hydroxyapatite; strontium chloride; verbal rating scale; visual analog scale.

PubMed Disclaimer

Conflict of interest statement

There are no conflicts of interest.

Figures

Figure 1
Figure 1
Flowchart showing study design. DL – Diode laser; DL+HAP – Diode laser+ Hydroxyapatite; ES – Electrosurgery; ES+HAP – Electrosurgery+Hydroxyapatite; DL+SrCl2 – Diode laser+Strontium chloride; ES+SrCl2 – Electrosurgery+ Strontium chloride; VRS – Verbal rating scale; VAS – Visual analogue scale
Figure 2
Figure 2
Firing of laser at the site
Figure 3
Figure 3
Application of electrode at the site

Similar articles

Cited by

References

    1. Holland GR, Narhi MN, Addy M, Gangarosa L, Orchardson R. Guidelines for the design and conduct of clinical trials on dentine hypersensitivity. J Clin Periodontol. 1997;24:808–13. - PubMed
    1. Trowbridge HO, Silver DR. A review of current approaches to in-office management of tooth hypersensitivity. Dent Clin North Am. 1990;34:561–81. - PubMed
    1. Orologio GD, Lone A, Finger WJ. Clinical evaluation of the role of glutaraldehyde in a one-bottle adhesive. Am J Dent. 2002;15:330–4. - PubMed
    1. Keele KD. The pain chart. Lancet. 1948;2:6–8. - PubMed
    1. Price DD, McGrath PA, Rafii A, Buckingham B. The validation of visual analogue scales as ratio scale measures for chronic and experimental pain. Pain. 1983;17:45–56. - PubMed