Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 May;85(5):2882-2891.
doi: 10.1002/mrm.28662. Epub 2021 Jan 12.

Elastomer coils for wearable MR detection

Affiliations

Elastomer coils for wearable MR detection

Andreas Port et al. Magn Reson Med. 2021 May.

Abstract

Purpose: To explore the use of conductive elastomer for MR signal detection and the utility of this approach for wearable detector arrays.

Methods: An elastomer filled with silver microparticles was used to form stretchable radiofrequency coils for MR detection. Their electrical performance in terms of the Qunloaded and Q ratio was assessed in the relaxed state and under repeated strain up to 40%. In a phantom imaging study, the signal-to-noise ratio yield of conductive elastomer coils was compared with that of a reference copper coil. Four elastomer coils were integrated with a stretchable textile substrate to form a wearable array for knee imaging. The array was employed for multiple-angle and kinematic knee imaging in vivo.

Results: The elastomer coils proved highly stretchable and mechanically robust. Upon repeated stretching by 20%, a medium-sized coil element settled at Qunloaded of 42 in the relaxed state and 32 at full strain, reflecting sample-noise dominance. The signal-to-noise ratio of elastomer coils was found to be 8% to 16% lower than that achieved with a conventional copper coil. Multiple-angle and kinematic knee imaging with the wearable array yielded high-quality results indicating robustness of detection performance against stretching and warping of the array.

Conclusion: Conductive elastomer is a viable material for MR detection. Coils made from this material reconcile high stretchability and adequate electrical performance with ease of manufacturing. Conductive elastomer also offers inherent restoring forces and is readily washable and sanitizable, making it an excellent basis of wearable detector front ends.

Keywords: conductive elastomer; knee imaging; wearable array.

PubMed Disclaimer

References

REFERENCES

    1. Kwok WE, Lo KK, Seo G, Totterman SMS. A volume adjustable four-coil phased array for high resolution MR imaging of the hip. Magn Reson Mater Physics, Biol Med. 1999;9:59-64.
    1. Adriany G, Van De Moortele PF, Ritter J, et al. A geometrically adjustable 16-channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla. Magn Reson Med. 2008;59:590-597.
    1. Nordmeyer-Massner JA, De Zanche N, Pruessmann KP. Mechanically adjustable coil array for wrist MRI. Magn Reson Med. 2009;61:429-438.
    1. Lopez Rios N, Foias A, Lodygensky G, Dehaes M, Cohen-Adad J. Size-adaptable 13-channel receive array for brain MRI in human neonates at 3 T. NMR Biomed. 2018;31:e3944.
    1. Zhang B, Brown R, Cloos M, Lattanzi R, Sodickson D, Wiggins G. Size-adaptable, “Trellis” structure for tailored MRI coil arrays. Magn Reson Med. 2019;81:3406-3415.

Publication types

LinkOut - more resources