Repeatability of automated measurements by a new anterior segment optical coherence tomographer and biometer and agreement with standard devices

Affiliations

Repeatability of automated measurements by a new anterior segment optical coherence tomographer and biometer and agreement with standard devices

Domenico Schiano-Lomoriello et al. Sci Rep. .

Abstract

We assess repeatability of automatic measurements of a new anterior segment optical coherence tomographer and biometer (ANTERION) and their agreement with those provided by an anterior segment-optical coherence tomography device combined with Placido-disk corneal topography (MS-39) and a validated optical biometer (IOLMaster 500). A consecutive series of patients underwent three measurements with ANTERION and one with MS-39. A subgroup of patients underwent biometry also with IOLMaster 500. Repeatability was assessed by means of within-subject standard deviation, coefficient of variation (COV), and intraclass correlation coefficient (ICC). Agreement was investigated with the 95% limits of agreement. Paired t-test and Wilcoxon matched-pairs test were performed to compare the measurements of the different devices. Repeatability of ANTERION measurements was high, with ICC > 0.98 for all parameters except astigmatism (0.963); all parameters apart from those related to astigmatism revealed a COV < 1%. Repeatability of astigmatism improved when only eyes whose keratometric astigmatism was higher than 1.0 D were investigated. Most measurements by ANTERION and MS-39 showed good agreement. No significant differences were found between measurements by ANTERION and IOLMaster, but for corneal diameter. ANTERION revealed high repeatability of automatic measurements and good agreement with both MS-39 and IOLMaster for most parameters.

PubMed Disclaimer

Conflict of interest statement

Dr. Hoffer licenses the registered trademark name Hoffer to ensure accurate programming of his formulas to Carl Zeiss-Meditec (IOLMasters), Haag-Streit (LenStar/EyeStar), Heidelberg Engineering (ANTERION), Oculus (Pentacam AXL), Movu (Argos), Nidek (AL-Scan), Oculus (Pentacam AXL), Tomey (OA-2000), Topcon EU/VISIA Imaging (Aladdin), Ziemer (Galilei G6) and all A-scan biometer manufacturers. Dr. Savini is a consultant to CSO and has received personal fees from Alcon, Oculus and Zeiss. The remaining authors have no financial disclosures.

Similar articles

Cited by

References

    1. Mohamed S, et al. Repeatability and reproducibility of pachymetric mapping with Visante anterior segment—optical coherence tomography. Invest. Ophthalmol. Vis. Sci. 2007;48:5499–5504. doi: 10.1167/iovs.07-0591. - DOI - PubMed
    1. Ang M, et al. Anterior segment optical coherence tomography. Prog. Retin. Eye Res. 2018;66:132–156. doi: 10.1016/j.preteyeres.2018.04.002. - DOI - PubMed
    1. Savini G, Schiano-Lomoriello D, Hoffer KJ. Repeatability of automatic measurements by a new anterior segment optical coherence tomographer combined with Placido topography and agreement with 2 Scheimpflug cameras. J Cataract Refract Surg. 2018;44:471–478. doi: 10.1016/j.jcrs.2018.02.015. - DOI - PubMed
    1. Tang M, Chen A, Li Y, Huang D. Corneal power measurement with Fourier-domain optical coherence tomography. J. Cataract. Refract. Surg. 2010;36:2115–2122. doi: 10.1016/j.jcrs.2010.07.018. - DOI - PMC - PubMed
    1. Mansoori T, Balakrishna N. Intrasession repeatability of pachymetry measurements with RTVue XR 100 optical coherence tomography in normal cornea. Saudi J. Ophthalmol. 2017;31:65–68. doi: 10.1016/j.sjopt.2017.04.003. - DOI - PMC - PubMed

Publication types

LinkOut - more resources