Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jan 14;11(1):1410.
doi: 10.1038/s41598-020-80838-5.

Post-gel polymerisation shrinkage profiling of polymer biomaterials using a chirped fibre Bragg grating

Affiliations

Post-gel polymerisation shrinkage profiling of polymer biomaterials using a chirped fibre Bragg grating

Ginu Rajan et al. Sci Rep. .

Abstract

A strain profile measurement technique using a chirped fibre Bragg grating (CFBG) sensor by implementing an integration of differences (IOD) method is reported in this paper. Using the IOD method the spatial distribution of strain along the length of the CFBG is extracted from its power reflectance spectra. As a proof of concept demonstration, the developed technique is applied to measure the polymerisation shrinkage strain profile of a photo-cured polymer dental composite which exhibits a non-uniform strain distribution attributed to the curing lamp characteristics. The result from the CFBG technique is compared with that of an FBG array embedded in the dental composite and is correlated with the degree of conversion of the material which also depends on the curing lamp intensity distribution. This technology will have significant impact and applications in a range of medical, materials and engineering areas where strain or temperature gradient profile measurement is required in smaller scales.

PubMed Disclaimer

Conflict of interest statement

The authors declare no competing interests.

Figures

Figure 1
Figure 1
A flowchart of the process involved in measuring strain/temperature profile from a CFBG.
Figure 2
Figure 2
(a) Schematic experimental arrangement, (b) photograph of the setup.
Figure 3
Figure 3
(a) PS strain profile of the dental composite measured using CFBG sensor, (b) PS strain response at 5 mm location of the dental composite specimen measured by the CFBG.
Figure 4
Figure 4
(a) Changes in the CFBG spectra due to PS strain, (b) evolution of PS strain within the dental composite for a duration of 10 min from cure initiation measured by the CFBG sensor.
Figure 5
Figure 5
(a) PS strain response at three locations of the dental composite measured by the FBG array, (b) comparison of post-gel volumetric PS of the dental composite measured by CFBG sensor and FBG sensor array.

Similar articles

Cited by

References

    1. Xu X, He L, Zhu B, Li J. Advances in polymeric materials for dental applications. Polym. Chem. 2017;8:807–823. doi: 10.1039/C6PY01957A. - DOI
    1. Rueggeberg FA, Giannini M, Arrais CAG, Price RBT. Light curing in dentistry and clinical implications: a literature review. Braz. Oral Res. 2017;31:e61. doi: 10.1590/1807-3107bor-2017.vol31.0061. - DOI - PubMed
    1. Watts DC, Marouf AS, Al-Hindi AM. Photo-polymerization shrinkage-stress kinetics in resin-composites: methods and development. Dent. Mater. 2003;19:1–11. doi: 10.1016/S0109-5641(02)00123-9. - DOI - PubMed
    1. Maas AS, Alania Y, Natale LC, Rodrigues MC, Watts DC, Braga RR. Trends in restorative composites research: what is in the future? Braz. Oral Res. 2017;31:e55. doi: 10.1590/1807-3107bor-2017.vol31.0055. - DOI - PubMed
    1. Schneider LFJ, Cavalcante LM, Silikas N. Shrinkage stresses generated during resin-composite applications: a review. J. Dent. Biomech. 2010;2010:131630. - PMC - PubMed

Publication types