Hepatic Elastometry and Glissonian Line in the Assessment of Liver Fibrosis
- PMID: 33451815
- DOI: 10.1016/j.ultrasmedbio.2020.12.015
Hepatic Elastometry and Glissonian Line in the Assessment of Liver Fibrosis
Abstract
The aim of this study was to identify a method for staging hepatic fibrosis using a non-invasive, rapid and inexpensive technique based on ultrasound morphologic hepatic features. A total of 215 patients with different liver diseases underwent B-mode (2-D brightness mode) ultrasonography, vibration-controlled transient elastography, 2-D shear wave elastography and measurement of the controlled attenuation parameter with transient elastography. B-Mode images of the anterior margin of the left lobe were obtained and processed with automatic Genoa Line Quantification (GLQ) software based on a neural network for staging liver fibrosis. The accuracy of GLQ was 90.6% during model training and 78.9% in 38 different patients with concordant elastometric measures. Receiver operating characteristic curve analysis of GLQ performance using vibration-controlled transient elastography as a reference yielded areas under the curves of 0.851 for F ≥ F1, 0.793 for F ≥ F2, 0.784 for F ≥ F3 and 0.789 for F ≥ F4. GLQ has the potential to be a rapid, easy-to-perform and tolerable method in the staging of liver fibrosis.
Keywords: Fibrosis staging; Liver fibrosis; Neural networks; Transient elastography.
Copyright © 2020 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Evaluation of acoustic radiation force impulse elastography for fibrosis staging of chronic liver disease: a pilot study.Liver Int. 2010 Apr;30(4):538-45. doi: 10.1111/j.1478-3231.2009.02130.x. Epub 2009 Oct 27. Liver Int. 2010. PMID: 19874490
-
Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study.Hepatology. 2012 Dec;56(6):2125-33. doi: 10.1002/hep.25936. Epub 2012 Aug 31. Hepatology. 2012. PMID: 22767302
-
Quantification of ultrasound imaging in the staging of hepatic fibrosis.Panminerva Med. 2018 Jun;60(2):44-51. doi: 10.23736/S0031-0808.18.03416-X. Epub 2018 Feb 13. Panminerva Med. 2018. PMID: 29442483
-
Accuracy of FibroScan Controlled Attenuation Parameter and Liver Stiffness Measurement in Assessing Steatosis and Fibrosis in Patients With Nonalcoholic Fatty Liver Disease.Gastroenterology. 2019 May;156(6):1717-1730. doi: 10.1053/j.gastro.2019.01.042. Epub 2019 Jan 25. Gastroenterology. 2019. PMID: 30689971
-
Assessment of biopsy-proven liver fibrosis by two-dimensional shear wave elastography: An individual patient data-based meta-analysis.Hepatology. 2018 Jan;67(1):260-272. doi: 10.1002/hep.29179. Epub 2017 Nov 15. Hepatology. 2018. PMID: 28370257 Free PMC article. Review.
Cited by
-
Artificial intelligence-based ultrasound imaging technologies for hepatic diseases.ILIVER. 2022 Nov 16;1(4):252-264. doi: 10.1016/j.iliver.2022.11.001. eCollection 2022 Dec. ILIVER. 2022. PMID: 40636352 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous