Neutron dosimetry and shielding verification in commissioning of Compact Proton Therapy Centers (CPTC) using MCNP6.2 Monte Carlo code
- PMID: 33451908
- DOI: 10.1016/j.apradiso.2020.109279
Neutron dosimetry and shielding verification in commissioning of Compact Proton Therapy Centers (CPTC) using MCNP6.2 Monte Carlo code
Abstract
Proton therapy (PT) is an external radiotherapy using proton beams with energies between 70 and 230 MeV to treat some type of tumours with outstanding benefits, due to its energy transfer plot. There is a growing demand of facilities taking up small spaces and Compact Proton Therapy Centers (CPTC), with one or two treatment rooms, supposing the technical response of manufacturers to this request. A large amount of stray radiation is produced in the interaction of protons used in therapy, neutrons mainly, hence, optimal design of shielding and verifications must be carried out in commissioning stages. Currently, almost 50 CPTC are under construction and start up in many countries, including several in Spain. In the present work, the effectiveness of shielding in a CPTC was verified with the Monte Carlo code MCNP6 by calculating the ambient dose equivalent, H*(10) due to secondary neutrons, outside the enclosures and walls of the center. The facility modelled was similar to one planned to start operating in 2019 in Spain, a CPTC, made up of a superconducting synchrocyclotron and one treatment room, with a configuration standard, shielding and width of barriers based on dimensions proposed a priori by the vendor. Therefore, the paper is focused in check the suitability of the materials and thickness of the walls of the center and develop the assessment of enclosures. Several models of the radiation sources and type of concrete in walls were simulated, starting from a conservative assumptions, followed by more realistic models. In all cases, the results were below 1 mSv/year, which is the international legal limit considered for the general public. This work is part of the project Contributions to Shielding and Dosimetry of Neutrons in Compact Proton Therapy Centers (CPTC).
Keywords: Ambient dose equivalent; Compact proton therapy centers; MCNP6.2; Operational radiation protection; Shielding commissioning.
Copyright © 2020 Elsevier Ltd. All rights reserved.
Similar articles
-
Benchmarking of stray neutron fields produced by synchrocyclotrons and synchrotrons in compact protontherapy centers (CPTC) using MCNP6 Monte Carlo code.Appl Radiat Isot. 2023 Mar;193:110645. doi: 10.1016/j.apradiso.2022.110645. Epub 2022 Dec 31. Appl Radiat Isot. 2023. PMID: 36642038
-
Monte Carlo characterization and benchmarking of extended range REM meters for its application in shielding and radiation area monitoring in Compact Proton Therapy Centers (CPTC).Appl Radiat Isot. 2019 Oct;152:115-126. doi: 10.1016/j.apradiso.2019.07.001. Epub 2019 Jul 2. Appl Radiat Isot. 2019. PMID: 31295682
-
Shielding implications for secondary neutrons and photons produced within the patient during IMPT.Med Phys. 2013 Jul;40(7):071701. doi: 10.1118/1.4807089. Med Phys. 2013. PMID: 23822405
-
Dosimetry of clinical neutron and proton beams: an overview of recommendations.Radiat Prot Dosimetry. 2004;110(1-4):565-72. doi: 10.1093/rpd/nch221. Radiat Prot Dosimetry. 2004. PMID: 15353710 Review.
-
Neutron dose and its measurement in proton therapy-current State of Knowledge.Br J Radiol. 2020 Mar;93(1107):20190412. doi: 10.1259/bjr.20190412. Epub 2020 Jan 21. Br J Radiol. 2020. PMID: 31868525 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources