Accuracy of Fibula Reconstruction Using Patient-Specific Cad/Cam Plates: A Multicenter Study on 47 Patients
- PMID: 33452834
- DOI: 10.1002/lary.29379
Accuracy of Fibula Reconstruction Using Patient-Specific Cad/Cam Plates: A Multicenter Study on 47 Patients
Abstract
Objectives: This prospective study evaluated the accuracy of mandibular reconstruction using free fibular flaps (by comparing virtual plans to the three-dimensional postoperative results), and the extent of bone-to-bone contact after computer-assisted surgery.
Methods: We included 65 patients who underwent partial-continuity mandibular resections from February 2013 to January 2017, and evaluated virtual planning, surgical techniques, and accuracy.
Results: Forty-seven patients were analysed. A total of 112 fibular segments received 54 implants. We measured 227 distances between landmarks to assess the accuracy of reconstruction. Postoperative reconstruction accuracy ranged from 0.5 to 3 mm.
Conclusion: Virtual surgical planning very accurately translated simulation into reality, particularly in patients requiring large, complex mandibular reconstructions using multiple fibular segments.
Level of evidence: 4 Laryngoscope, 131:E2169-E2175, 2021.
Keywords: CAD/CAM; accuracy of reconstruction; fibula flap; mandibular reconstruction; reconstruction surgery.
© 2021 The American Laryngological, Rhinological and Otological Society, Inc.
References
REFERENCES
-
- Tarsitano A, Del Corso G, Ciocca L, et al. Mandibular reconstructions using computer-aided design/computer-aided manufacturing: a systematic review of a defect-based reconstructive algorithm. J Craniomaxillofac Surg 2015;43:1785-1791.
-
- Zheng GS, Su YX, Liao GQ, et al. Mandible reconstruction assisted by preoperative simulation and transferring templates: cadaveric study of accuracy. J Oral Maxillofac Surg 2012;70:1480-1485.
-
- Hanasono MM, Skoracki RJ. Computer-assisted design and rapid prototype modeling in microvascular mandible reconstruction. Laryngoscope 2013;123:597-604.
-
- Hirsch DL, Garfein ES, Christensen AM, Weimer KA, Saddeh PB, Levine JP. Use of computeraided design and computer-aided manufacturing to produce orthognathically ideal surgical outcomes: a paradigm shift in head and neck reconstruction. J Oral Maxillofac Surg 2009;67:2115-2122.
-
- Toto JM, Chang EI, Agag R, Devarajan K, Patel SA, Topham NS. Improved operative efficiency of free fibula flap mandible reconstruction with patientspecific, computer-guided preoperative planning. Head Neck 2015;37:1660-1664.