Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Aug 10;6(8):4714-4721.
doi: 10.1021/acsbiomaterials.0c00632. Epub 2020 Jul 17.

Label-Free, Real-Time Phospholipase-A Isoform Assay

Affiliations

Label-Free, Real-Time Phospholipase-A Isoform Assay

Alvaro Garcia et al. ACS Biomater Sci Eng. .

Abstract

Phospholipase-A (PLA) enzymes catalyze the hydrolysis of ester bonds in select glycerophospholipids. Sensors for rapidly measuring the PLA activity in biological samples have relevance in the study of venom compositions and in medical diagnostics for the diagnosis of diseases such as acute pancreatitis. Current PLA sensor technologies are often restricted by the time it takes to prepare an assay, the necessity of using fluorescent labels, or the fact they might require strict pH control of the buffer vehicles used. Here we present a tethered bilayer lipid membrane (tBLM) impedance sensor array for the rapid and real-time detection of PLA, which includes the ability to selectively detect phospholipase-A2 (PLA2) from phospholipase-A1 (PLA1) isoforms. Comparing the activity of PLA1 and PLA2 in an array of tBLMs composed of ether phospholipids, ester phospholipids or ether-ester phospholipids allows for the rapid and reliable distinction between the isoforms, as measured using swept-frequency electrical impedance spectroscopy. After testing the assay using pure enzymes, we demonstrate the capacity of the sensor to identify specific PLA2-type, calcium-dependent activity from the venom of the South American bullet ant, Paraponera clavata, at a concentration of 1 μg/mL. The specificity of the phospholipase activity was corroborated using matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry. As further validation, we tested the activities of a PLA1 isoform in the presence of different buffers commonly used in biology and biochemistry experiments. Sensitivity testing shows that PLA1 can be detected at an activity as low as 0.06 U/mL. The rapid and reliable detection of phospholipases presented in this study has potential applications in the study of animal venoms as well as in lipase bioreactors and point-of-care devices.

Keywords: diether lipids; electrical impedance spectroscopy (EIS); ester lipids; phospholipase; tethered bilayer lipid membranes (tBLMs); venom.

PubMed Disclaimer

Publication types

LinkOut - more resources