Cage-screw and anterior plating combination reduces the risk of micromotion and subsidence in multilevel anterior cervical discectomy and fusion-a finite element study
- PMID: 33460810
- DOI: 10.1016/j.spinee.2021.01.015
Cage-screw and anterior plating combination reduces the risk of micromotion and subsidence in multilevel anterior cervical discectomy and fusion-a finite element study
Abstract
Background context: Anterior cervical discectomy and fusion (ACDF) is widely used to treat patients with spinal disorders, where the cage is a critical component to achieve satisfactory fusion results. However, it is still not clear whether a cage with screws or without screws will be the best choice for long-term fusion as the micromotion (sliding distance) and subsidence (penetration) of the cage still take place repeatedly.
Purpose: This study aims to examine the effect of cage-screws on the biomechanical characteristics of the human spine, implanted cage, and associate hardware by comparing the micromotion and subsidence.
Study design: A finite element (FE) analysis study.
Methods: A FE model of a C3-C5 cervical spine with ACDF was developed. The spinal segment was modeled with the removal of the anterior longitudinal ligament (ALL), posterior longitudinal ligament (PLL), and discectomy was then implanted with a cage-screw system. Three models were analyzed: the first was the original spine (S1 model), the second, S2, was implanted with cages and anterior plating, and the third, S3, was implanted with a cage-screw system in addition to the anterior plate. All investigations were under 1 N•m in flexion, extension, lateral bending, and axial rotation situations.
Results: Finite element analysis (FEA) demonstrated that range of motion (ROM) at C3-C4 in the S2 model was significantly reduced more than that in the S3 model, while the ROM at both C4-C5 in the S3 model was reduced more than that in the S2 model in all simulations. The ROM at C3-C5 in the S1 model was reduced by over 5° in the S2 and S3 models in all loading conditions. The micromotion and subsidence at all contacts of C3-C5 in the S3 model were lower than that in the S2 model in all flexion, extension, bending, and axial simulations. The subsidence and micromotion could be seen in the barrier area of the S2 model, while they occurred near the edge of the screw in the S3 model.
Conclusions: These results showed that the cage-screw and anterior plating combination has promising potential to reduce the risk of micromotion and subsidence of implanted cages in two or more level ACDFs.
Clinical significance: The use of double segmental fixation with cage-screw anterior plating combination constructs may increase the stiffness of the construct and reduce the incidence of clinical and radiographic pseudarthrosis following multilevel ACDF, which in turn, could decrease the need for revision surgeries or supplemental posterior fixation.
Keywords: ACDF; Cervical spine; Finite element analysis; Micromotion; ROM; Subsidence.
Copyright © 2021 Elsevier Inc. All rights reserved.
Similar articles
-
Finite Element Analysis of the Effect of Dynamic Plating on Two-Level Anterior Cervical Discectomy Fusion Biomechanics.World Neurosurg. 2022 Jul;163:e43-e52. doi: 10.1016/j.wneu.2022.02.032. Epub 2022 Feb 14. World Neurosurg. 2022. PMID: 35176523
-
Biomechanical comparison of anterior cervical spine instrumentation techniques with and without supplemental posterior fusion after different corpectomy and discectomy combinations: Laboratory investigation.J Neurosurg Spine. 2012 Jun;16(6):579-84. doi: 10.3171/2012.2.SPINE11611. Epub 2012 Mar 16. J Neurosurg Spine. 2012. PMID: 22423633
-
Adjacent segment biomechanical changes after one- or two-level anterior cervical discectomy and fusion using either a zero-profile device or cage plus plate: A finite element analysis.Comput Biol Med. 2020 May;120:103760. doi: 10.1016/j.compbiomed.2020.103760. Epub 2020 Apr 18. Comput Biol Med. 2020. PMID: 32421657
-
Incidence and clinical relevance of cage subsidence in anterior cervical discectomy and fusion: a systematic review.Acta Neurochir (Wien). 2018 Apr;160(4):873-880. doi: 10.1007/s00701-018-3490-3. Epub 2018 Feb 21. Acta Neurochir (Wien). 2018. PMID: 29468440 Free PMC article.
-
Incidence of Subsidence of Seven Intervertebral Devices in Anterior Cervical Discectomy and Fusion: A Network Meta-Analysis.World Neurosurg. 2020 Sep;141:479-489.e4. doi: 10.1016/j.wneu.2020.03.130. Epub 2020 Apr 3. World Neurosurg. 2020. PMID: 32251812 Review.
Cited by
-
A New Method to Evaluate Pressure Distribution Using a 3D-Printed C2-C3 Cervical Spine Model with an Embedded Sensor Array.Sensors (Basel). 2023 Dec 1;23(23):9547. doi: 10.3390/s23239547. Sensors (Basel). 2023. PMID: 38067922 Free PMC article.
-
Biomechanical study of anterior transpedicular root screw intervertebral fusion system of lower cervical spine: a finite element analysis.Front Bioeng Biotechnol. 2024 Jan 31;12:1352996. doi: 10.3389/fbioe.2024.1352996. eCollection 2024. Front Bioeng Biotechnol. 2024. PMID: 38357708 Free PMC article.
-
A Review of Finite Element Modeling for Anterior Cervical Discectomy and Fusion.Asian Spine J. 2023 Oct;17(5):949-963. doi: 10.31616/asj.2022.0295. Epub 2023 Jul 6. Asian Spine J. 2023. PMID: 37408489 Free PMC article.
-
Factors influencing cage subsidence in anterior cervical corpectomy and discectomy: a systematic review.Eur Spine J. 2023 Mar;32(3):957-968. doi: 10.1007/s00586-023-07530-w. Epub 2023 Jan 28. Eur Spine J. 2023. PMID: 36708398
-
Impact of screw tip design on screw anchorage: mechanical testing and numerical simulation.J Orthop Surg Res. 2024 Jul 30;19(1):447. doi: 10.1186/s13018-024-04841-6. J Orthop Surg Res. 2024. PMID: 39080768 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous