Fixation of displaced subcapital femoral fractures. Compression screw fixation versus double divergent pins
- PMID: 3346287
- DOI: 10.1302/0301-620X.70B2.3346287
Fixation of displaced subcapital femoral fractures. Compression screw fixation versus double divergent pins
Abstract
One hundred and twenty-seven consecutive patients with displaced subcapital fractures of the femoral neck (Garden Grade III or IV) all under 80 years of age and independently mobile, were randomly allocated to fixation with either double divergent pins or a single sliding screw-plate device. The incidence of non-union and infection in the sliding screw-plate group was significantly higher, and we believe that when internal fixation is considered appropriate multiple pinning should be used. Mobility after treatment was disappointing in about half of the patients, and we feel that internal fixation can only be justified in patients who are physiologically well preserved and who maintain a high level of activity.
Similar articles
-
Treatment of femoral neck fractures with a sliding compression screw and two Knowles pins.Clin Orthop Relat Res. 1984 Nov;(190):158-62. Clin Orthop Relat Res. 1984. PMID: 6488626
-
Minimally displaced intra-capsular femoral neck fractures in the elderly--comparison of multiple threaded pins and sliding compression screws surgical techniques.J Orthop Surg (Hong Kong). 2003 Dec;11(2):129-36. doi: 10.1177/230949900301100205. J Orthop Surg (Hong Kong). 2003. PMID: 14676336
-
Compression screw fixation for displaced subcapital fracture of the femur. Success or failure?J Bone Joint Surg Br. 1986 Jan;68(1):78-82. doi: 10.1302/0301-620X.68B1.3941145. J Bone Joint Surg Br. 1986. PMID: 3941145
-
Fractures of the femoral neck: a review and personal statement.Acta Chir Orthop Traumatol Cech. 2006;73(1):45-59. Acta Chir Orthop Traumatol Cech. 2006. PMID: 16613748 Review.
-
Minimally invasive surgery for femoral neck fractures using bone cement infusible hollow-perforated screw in high-risk patients with advanced cancer.Surg Oncol. 2015 Sep;24(3):226-31. doi: 10.1016/j.suronc.2015.05.003. Epub 2015 May 22. Surg Oncol. 2015. PMID: 26051408 Review.
Cited by
-
Internal fixation implants for intracapsular hip fractures in older adults.Cochrane Database Syst Rev. 2021 Mar 9;3(3):CD013409. doi: 10.1002/14651858.CD013409.pub2. Cochrane Database Syst Rev. 2021. PMID: 33687067 Free PMC article.
-
Internal fixation implants for intracapsular proximal femoral fractures in adults.Cochrane Database Syst Rev. 2001;2001(4):CD001467. doi: 10.1002/14651858.CD001467. Cochrane Database Syst Rev. 2001. PMID: 11687113 Free PMC article.
-
Comparative study of fresh femoral neck fractures managed by multiple cancellous screws with and without fibular graft in young adults.J Clin Orthop Trauma. 2015 Mar;6(1):6-11. doi: 10.1016/j.jcot.2014.12.008. Epub 2015 Jan 7. J Clin Orthop Trauma. 2015. PMID: 26549945 Free PMC article.
-
Dynamic hip screws versus cannulated screws for femoral neck fractures: a systematic review and meta-analysis.J Orthop Surg Res. 2020 Aug 26;15(1):352. doi: 10.1186/s13018-020-01842-z. J Orthop Surg Res. 2020. PMID: 32843048 Free PMC article.
-
Functional outcome of modified Pauwels' intertrochanteric osteotomy and total hip arthroplasty in femoral neck fractures in elderly patients.Indian J Orthop. 2008 Jan;42(1):49-55. doi: 10.4103/0019-5413.38581. Indian J Orthop. 2008. PMID: 19823655 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources
Medical