Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jan 19;22(1):64.
doi: 10.1186/s13063-020-05002-w.

In silico imaging clinical trials: cheaper, faster, better, safer, and more scalable

Affiliations

In silico imaging clinical trials: cheaper, faster, better, safer, and more scalable

Aldo Badano. Trials. .

Abstract

Imaging clinical trials can be burdensome and often delay patient access to novel, high-quality medical devices. Tools for in silico imaging trials have significantly improved in sophistication and availability. Here, I describe some of the principal advantages of in silico imaging trials and enumerate five lessons learned during the design and execution of the first all-in silico virtual imaging clinical trial for regulatory evaluation (the VICTRE study).

Keywords: Computational modeling; In silico trials; Regulatory evaluation.

PubMed Disclaimer

Conflict of interest statement

The author declares that he has no competing interests.

Figures

Fig. 1
Fig. 1
Example image regions containing a lesion. (from left to right) A spiculated mass shown embedded in the same location of a digital breast model seen in a DM and DBT image. The absorption of the lesion has been increased to ensure conspicuity for this illustration. A microcalcification cluster embedded in the same location of a digital breast model seen in a DM and DBT image. The DBT images correspond to a slice of the three-dimensional volume obtained from reconstructing the multiple angular projections

Similar articles

Cited by

References

    1. Badano A. In silico imaging: definition, possibilities and challenges. Nucl Inst Methods Phys Res Part A. 2011;648:276–80. doi: 10.1016/j.nima.2010.11.054. - DOI
    1. Gong X, Glick SJ, Liu B, Vedula AA, Thacker S. A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging. Med Phys. 2006;33(4):1041–52. doi: 10.1118/1.2174127. - DOI - PubMed
    1. Badano A, Graff CG, Badal A, Sharma D, Zeng R, Samuelson FW, Glick SJ, Myers KJ. Evaluation of digital breast tomosynthesis as replacement of full-field digital mammography using an in silico imaging trial. JAMA Netw Open. 2018;1(7):185474. doi: 10.1001/jamanetworkopen.2018.5474. - DOI - PMC - PubMed
    1. Georgian-Smith D, Obuchowski NA, Lo JY, Brem RF, Baker JA, Fisher PR, Rim A, Zhao W, Fajardo LL, Mertelmeier T. Can Digital Breast Tomosynthesis Replace Full-Field Digital Mammography? A Multireader, Multicase Study of Wide-Angle Tomosynthesis. Am J Roentgenol. 2019;212(6):1393–9. doi: 10.2214/AJR.18.20294. - DOI - PubMed
    1. Zeng R, Samuelson FW, Sharma D, Badal A, Christian GG, Glick SJ, Myers KJ, Badano AG. Computational reader design and statistical performance evaluation of an in-silico imaging clinical trial comparing digital breast tomosynthesis with full-field digital mammography. J Med Imaging. 2020;7(4):1–18. doi: 10.1117/1.JMI.7.4.042802. - DOI - PMC - PubMed