Review
. 2021 Jan 25;14(2):115-134.
doi: 10.1016/j.jcin.2020.09.063.

Incidence, Predictors, and Implications of Permanent Pacemaker Requirement After Transcatheter Aortic Valve Replacement

Affiliations
Free article
Review

Incidence, Predictors, and Implications of Permanent Pacemaker Requirement After Transcatheter Aortic Valve Replacement

Yasser Sammour et al. JACC Cardiovasc Interv. .
Free article

Abstract

Transcatheter aortic valve replacement (TAVR) is a safe and feasible alternative to surgery in patients with symptomatic severe aortic stenosis regardless of the surgical risk. Conduction abnormalities requiring permanent pacemaker (PPM) implantation remain a common finding after TAVR due to the close proximity of the atrioventricular conduction system to the aortic root. High-grade atrioventricular block and new onset left bundle branch block (LBBB) are the most commonly reported conduction abnormalities after TAVR. The overall rate of PPM implantation after TAVR varies and is related to pre-procedural and intraprocedural factors. The available literature regarding the impact of conduction abnormalities and PPM requirement on morbidity and mortality is still conflicting. Pre-procedural conduction abnormalities such as right bundle branch block and LBBB have been linked with increased PPM implantation and mortality after TAVR. When screening patients for TAVR, heart teams should be aware of various anatomical and pathophysiological conditions that make patients more susceptible to increased risk of conduction abnormalities and PPM requirement after the procedure. This is particularly important as TAVR has been recently approved for patients with low surgical risk. The purpose of this review is to discuss the incidence, predictors, impact, and management of the various conduction abnormalities requiring PPM implantation in patients undergoing TAVR.

Keywords: PPM; TAVR; conduction disturbances; state-of-the-art.

PubMed Disclaimer

Conflict of interest statement

Author Disclosures The authors have reported that they have no relationships relevant to the contents of this paper to disclose.