Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1988 Mar;45(3):174-81.
doi: 10.1136/oem.45.3.174.

In vivo tibia lead measurements as an index of cumulative exposure in occupationally exposed subjects

Affiliations

In vivo tibia lead measurements as an index of cumulative exposure in occupationally exposed subjects

L J Somervaille et al. Br J Ind Med. 1988 Mar.

Abstract

In vivo tibia lead measurements of 20 non-occupationally exposed and 190 occupationally exposed people drawn from three factories were made using a non-invasive x ray fluorescence technique in which characteristic x rays from lead are excited by gamma rays from a cadmium-109 source. The maximum skin dose to a small region of the shin was 0.45 mSv. The relation between tibia lead and blood lead was weak in workers from one factory (r = 0.11, p greater than 0.6) and among the non-occupationally exposed subjects (r = 0.07, p greater than 0.7); however, a stronger relation was observed in the other two factories (r = 0.45, p less than 0.0001 and r = 0.53, p less than 0.0001). Correlation coefficients between tibia lead and duration of employment were consistently higher at all three factories respectively (r = 0.86, p less than 0.0001; r = 0.61, p less than 0.0001; r = 0.80, p less than 0.0001). A strong relation was observed between tibia lead and a simple, time integrated, blood lead index among workers from the two factories from which blood lead histories were available. The regression equation from two groups of workers (n = 88, 79) did not significantly differ despite different exposure conditions. The correlation coefficient for the combined data set (n = 167) was 0.84 (p less than 0.0001). This shows clearly that tibia lead, measured in vivo by x-ray fluorescence, provides a good indicator of long term exposure to lead as assessed by a cumulative blood lead index.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Br J Ind Med. 1975 Feb;32(1):1-10 - PubMed
    1. N Engl J Med. 1976 Mar 25;294(13):687-90 - PubMed
    1. Phys Med Biol. 1979 Jan;24(1):136-45 - PubMed
    1. Med Phys. 1983 Mar-Apr;10(2):248-51 - PubMed
    1. Br J Radiol. 1984 Jan;57(673):29-33 - PubMed

Publication types