. 2020 Sep 30;6(1):24-26.
doi: 10.1016/j.vgie.2020.08.009. eCollection 2021 Jan.

Endoscopic tamponade using a fully covered self-expandable metallic stent for massive biliary bleeding from a pseudoaneurysm rupture during metallic stent removal

Affiliations

Endoscopic tamponade using a fully covered self-expandable metallic stent for massive biliary bleeding from a pseudoaneurysm rupture during metallic stent removal

Nao Fujimori et al. VideoGIE. .
No abstract available

Keywords: CT, computed tomography; SEMS, self-expandable metallic stent; TAE, transcatheter arterial embolization.

PubMed Disclaimer

Figures

Figure 1
Figure 1
A, Abdominal CT shows a fully covered self-expandable metallic stent (SEMS, arrowhead) in the bile duct and a plastic stent (arrow) in the gallbladder. No biliary bleeding or pseudoaneurysm was observed. B, The endoscopic view shows SEMS occlusion by biliary sludge. We inserted an 8.5F plastic stent into the SEMS to resolve cholangitis.
Figure 2
Figure 2
A, The CT shows a 2-cm pseudoaneurysm (arrow) arising from a branch of gastroduodenal or proper hepatic arteries and located in a tumor of the pancreas that was not evident 2 weeks earlier. B, The pseudoaneurysm was just adjacent to the biliary self-expandable metallic stent.
Figure 3
Figure 3
Angiography showing a pseudoaneurysm (arrowhead) of the gastroduodenal artery (A), which was successfully treated with coil embolization (B).

References

    1. Tien T., Tan Y.C., Baptiste P. Haemobilia in a previously stented hilar cholangiocarcinoma: successful haemostasis after the insertion of fcSEMS. Oxf Med Case Reports. 2020:65–68. - PMC - PubMed
    1. Nezu Y., Nakaji S., Fujii H. Pseudoaneurysm caused by a self-expandable metal stent: a report of three cases. Endoscopy. 2014;46:248–251. - PubMed
    1. Satoh T., Matsubayashi H., Ishiwatari H. Rupture of pseudoaneurysm after biliary metallic stent placement. Intern Med. 2019;58:1453–1457. - PMC - PubMed
    1. Tsuji S., Itoi T., Sofuni A. Life-threatening hemorrhage from the papilla following stent removal (with video) J Hepatobiliary Pancreat Sci. 2011;18:751–753. - PubMed
    1. Tonozuka R., Itoi T., Sofuni A. Hemostasis using a fully covered self-expandable metal stent for marked bleeding from the bile duct following stent removal (with videos) J Hepatobil Pancreat Sci. 2013;20:254–256. - PubMed