. 2022 Jan 11;66(1):29-39.
doi: 10.2186/jpr.JPR_D_20_00184. Epub 2021 Jan 26.

The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors: A systematic review and meta-analysis

Affiliations
Free article
Meta-Analysis

The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors: A systematic review and meta-analysis

Ramadhan Hardani Putra et al. J Prosthodont Res. .
Free article

Abstract

Purpose: To review the current clinical studies regarding the accuracy of implant computer-guided surgery in partially edentulous patients and investigate potential influencing factors.

Study selection: Electronic searches on the PubMed and Cochrane Central Register of Controlled Trials databases, and subsequent manual searches were performed. Two reviewers selected the studies following our inclusion and exclusion criteria. Qualitative review and meta-analysis of the implant placement accuracy were performed to analyze potential influencing factors. Angular deviation, coronal deviation, apical deviation, and depth deviation were evaluated as the accuracy outcomes.

Results: Eighteen studies were included in this systematic review, including six randomized controlled trials, nine prospective studies, and three retrospective clinical studies. A total of 1317 implants placed in 642 partially edentulous patients were reviewed. Eight studies were evaluated using meta-analysis. Fully guided surgery showed statistically higher accuracy in angular (P <0.001), coronal (P <0.001), and apical deviation (P <0.05) compared with pilot-drill guided surgery. A statistically significant difference (P <0.001) was also observed in coronal deviation between the bounded edentulous (BES) and distal extension spaces (DES). A significantly lower angular deviation (P <0.001) was found in implants placed using computer-aided design/computer-aided manufacturing (CAD/CAM) compared to the conventional surgical guides.

Conclusion: The edentulous space type, surgical guide manufacturing procedure, and guided surgery protocol can influence the accuracy of computer-guided surgery in partially edentulous patients. Higher accuracy was found when the implants were placed in BES, with CAD/CAM manufactured surgical guides, using a fully guided surgery protocol.

Keywords: Accuracy; Computer guided surgery; Dental implant; Partially edentulous.

PubMed Disclaimer

Substances