The usefulness of a delivery catheter system for right ventricular "true" septal pacing
- PMID: 33507356
- DOI: 10.1007/s00380-021-01780-8
The usefulness of a delivery catheter system for right ventricular "true" septal pacing
Abstract
Right ventricular (RV) septum is an alternate site for the placement of RV lead tip instead of RV apex. Recent studies have demonstrated that less than half of the RV leads targeted for septal implantation are placed on the RV septum using a conventional stylet system; new guiding catheter systems have become available for RV lead placement. This study aimed to investigate the usefulness of the delivery catheter system in lead placement on the RV septum when compared with the stylet system. We retrospectively evaluated 198 patients who underwent fluoroscopically guided pacemaker implantation with RV leads targeted to be placed in the RV septum and in whom computed tomography was incidentally and subsequently performed. A delivery catheter was used in 16 patients, and a stylet in 182 patients. The primary endpoint of this study was the success rate of RV lead placement on the RV septum. The proportion of RV lead placement on the RV septum was higher in the delivery catheter group than in the stylet group (100% vs. 44%; p < 0.001). In the stylet group, the lead tips were placed at the hinge in 92 cases (51%) and on the free wall in 9 cases (5%). Paced QRS duration was narrower in the delivery catheter group than in the stylet group (128 ± 16 vs. 150 ± 21 ms, p < 0.01). The delivery catheter system designated for pacing leads may aid in selecting RV septal sites and achieve good physiologic ventricular activation.
Keywords: Bradycardia; Computed tomography; Delivery catheter; Pacemaker; Right ventricular septal pacing.
References
-
- Sweeney MO, Hellkamp AS, Ellenbogen KA, Greenspon AJ, Freedman RA, Lee KL, Lamas GA, MOde Selection Trial Investigators (2003) Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation 107:2932–2937 - DOI
-
- Nielsen JC, Kristensen L, Andersen HR, Mortensen PT, Pedersen OL, Pedersen AK (2003) A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome: echocardiographic and clinical outcome. J Am Coll Cardiol 42:614–623 - DOI
-
- Karpawich PP, Justice CD, Cavitt DL, Chang CH (1990) Developmental sequelae of fixed-rate ventricular pacing in the immature canine heart: an electrophysiologic, hemodynamic, and histopathologic evaluation. Am Heart J 119:1077–1083 - DOI
-
- Spath NB, Wang K, Venkatasumbramanian S, Fersia O, Newby DE, Lang CC, Grubb NR, Dweck MR (2019) Complications and prognosis of patients undergoing apical or septal right ventricular pacing. Open Heart 6:e000962 - DOI
-
- Mizukami A, Matsue Y, Naruse Y, Kowase S, Kurosaki K, Suzuki M, Matsumura A, Nogami A, Aonuma K, Hashimoto Y (2016) Implications of right ventricular septal pacing for medium-term prognosis: propensity-matched analysis. Int J Cardiol 220:214–218 - DOI
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous
