Comparison of the SRK II formula and other second generation formulas
- PMID: 3351749
- DOI: 10.1016/s0886-3350(88)80087-7
Comparison of the SRK II formula and other second generation formulas
Abstract
A simple modification of the SRK formula was developed for use with extreme axial length cases (short and long eyes) to maximize prediction accuracy in these groups. For "average" eyes (over 75% of all cases), SRK needed no modifications to maintain maximum predictive accuracy. The new, modified SRK formula (SRK II) was compared with current second generation formulas and the Binkhorst formula. The SRK II formula, while maintaining the simplicity and ease of the SRK, was comparable to and in some cases superior to the other formulas. Overall, 80.0% of 2,068 posterior chamber intraocular lenses from seven different manufacturers demonstrated less than one diopter of prediction error and only 0.5% had three or more diopters of error. In short eyes (less than 22 mm), 74.0% were corrected to within one diopter and less than 2.0% had three or more diopters of error. In long eyes (greater than or equal to 24.5 mm), 78.0% of cases demonstrated less than one diopter of error and less than 1.0% had three or more diopters of error. Although the SRK II formula is incorporated in most new A-scan units, the modifications are so simple that surgeons can take the standard SRK predictions and mentally calculate the modifications for extreme cases.
Similar articles
-
Comparison of the SRK/T formula and other theoretical and regression formulas.J Cataract Refract Surg. 1990 May;16(3):341-6. doi: 10.1016/s0886-3350(13)80706-7. J Cataract Refract Surg. 1990. PMID: 2355322
-
Effect of anterior chamber depth on the choice of intraocular lens calculation formula in patients with normal axial length.Middle East Afr J Ophthalmol. 2014 Oct-Dec;21(4):307-11. doi: 10.4103/0974-9233.142266. Middle East Afr J Ophthalmol. 2014. PMID: 25371635 Free PMC article.
-
A new posterior chamber intraocular lens formula for axial myopes.Ophthalmology. 1984 May;91(5):484-8. doi: 10.1016/s0161-6420(84)34263-4. Ophthalmology. 1984. PMID: 6739051
-
Meta-analysis of accuracy of intraocular lens power calculation formulas in short eyes.Clin Exp Ophthalmol. 2018 May;46(4):356-363. doi: 10.1111/ceo.13058. Epub 2017 Oct 10. Clin Exp Ophthalmol. 2018. PMID: 28887901 Review.
-
Accuracy of intraocular lens power calculation formulas in long eyes: a systematic review and meta-analysis.Clin Exp Ophthalmol. 2018 Sep;46(7):738-749. doi: 10.1111/ceo.13184. Epub 2018 Mar 24. Clin Exp Ophthalmol. 2018. PMID: 29498180
Cited by
-
Optimizing the intraocular lens formula constant according to intraocular lens diameter.Int J Ophthalmol. 2021 May 18;14(5):700-703. doi: 10.18240/ijo.2021.05.09. eCollection 2021. Int J Ophthalmol. 2021. PMID: 34012884 Free PMC article.
-
Intraocular lens calculations in atypical eyes.Indian J Ophthalmol. 2017 Dec;65(12):1289-1293. doi: 10.4103/ijo.IJO_834_17. Indian J Ophthalmol. 2017. PMID: 29208808 Free PMC article. Review.
-
Achromatic doublet intraocular lens for full aberration correction.Biomed Opt Express. 2017 Apr 5;8(5):2396-2404. doi: 10.1364/BOE.8.002396. eCollection 2017 May 1. Biomed Opt Express. 2017. PMID: 28663881 Free PMC article.
-
Paediatric intraocular lens implants: accuracy of lens power calculations.Eye (Lond). 2016 Sep;30(9):1215-20. doi: 10.1038/eye.2016.163. Epub 2016 Jul 29. Eye (Lond). 2016. PMID: 27472214 Free PMC article.
-
SRK II formula in the calculation of intraocular lens power.Br J Ophthalmol. 1989 Oct;73(10):823-6. doi: 10.1136/bjo.73.10.823. Br J Ophthalmol. 1989. PMID: 2818992 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials