Randomized Controlled Trial
. 2021 May;36(5):1584-1589.e1.
doi: 10.1016/j.arth.2021.01.013. Epub 2021 Jan 12.

A Prospective Randomized Controlled Trial Comparing Medial-Pivot versus Posterior-Stabilized Total Knee Arthroplasty

Affiliations
Randomized Controlled Trial

A Prospective Randomized Controlled Trial Comparing Medial-Pivot versus Posterior-Stabilized Total Knee Arthroplasty

Justin S Chang et al. J Arthroplasty. 2021 May.

Abstract

Background: The medial-pivot (MP) design for total knee arthroplasty (TKA) aims to restore more natural "ball-and-socket" knee kinematics compared to the traditional posterior-stabilized (PS) implants for TKA. The objective of this study is to determine if there was any difference in functional outcomes between patients undergoing MP-TKA vs PS-TKA.

Methods: This prospective randomized controlled trial consisted of 43 patients undergoing MP-TKA vs 45 patients receiving a single-radius PS-TKA design. The primary outcome was postoperative range of motion (ROM). Secondary outcomes included the Western Ontario and McMaster Universities Arthritis Index, Oxford Knee Score, Knee Society Score (KSS), and radiological outcomes. All study patients were followed-up for 2 years after surgery.

Results: Patients undergoing MP-TKA had comparable ROM at 1 year (114.6° ± 16.3° vs 111.3° ± 17.8° respectively, P = .88) and 2 years after surgery (114.9° ± 15.5° vs 114.9° ± 16.4° respectively, P = .92) compared to PS-TKA. There were also no differences in Western Ontario and McMaster Universities Arthritis Index (26.8 ± 19.84 vs 22.0 ± 12.03 respectively, P = .14), Oxford Knee Score (42.7 ± 8.1 vs 42.3 ± 6.7 respectively, P = .18), KSS clinical scores (82.9 ± 16.96 vs 81.42 ± 10.45 respectively, P = .12) and KSS functional scores (76.2 ± 18.81 vs 73.93 ± 8.53 respectively, P = .62) at 2-year follow-up. There was no difference in postoperative limb alignment or complications.

Conclusion: This study demonstrated excellent results in both the single-radius PS-TKA design and MP-TKA design. No differences were identified at 2-year follow-up with respect to postoperative ROM and patient-reported outcome measures.

Keywords: medial-pivot; posterior-stabilized; primary total knee arthroplasty; randomized controlled trial; total knee arthroplasty design.