. 2022 Dec;70(8):645-651.
doi: 10.1055/s-0041-1723000. Epub 2021 Feb 4.

Ovine Biosynthetic Grafts for Aortoiliac Reconstructions in Nonsterile Operative Fields

Affiliations

Ovine Biosynthetic Grafts for Aortoiliac Reconstructions in Nonsterile Operative Fields

Hazem El Beyrouti et al. Thorac Cardiovasc Surg. 2022 Dec.

Abstract

Background: Prosthetic vascular grafts placed surgically or via endovascular techniques can be subject to the risk of life-threatening graft infections. The Omniflow II vascular prosthesis is a biosynthetic graft that was reported to have favorable properties in resisting infections.

Materials and methods: We retrospectively reviewed our 3 years' experience of using the Omniflow II prostheses for aortoiliac reconstructions in patients considered to carry a substantial risk of subsequent prosthetic graft infections (prevention group) as well as in patients with actively infected prosthetic vascular grafts (treatment group).

Results: Aorto-bi-iliac (n = 4) and aortobifemoral (n = 12) vascular reconstructions were performed using bifurcated Omniflow II prostheses in nine patients in the prevention group and seven patients in the treatment group. During mean follow-up of 28.6 ± 17.2 months, there was one case of graft infection (6.3%) and graft thrombosis (6.3%) with subsequent successful thrombectomy. Early and late surgical revisions were required in eight (50%) and two (12.6%) patients, respectively. All graft prostheses were patent at last follow-up.

Conclusion: Using bifurcated Omniflow II vascular prostheses in patients with or at a high risk of vascular graft infection is advisable, and is associated with acceptable reinfection and patency rates.

PubMed Disclaimer

Conflict of interest statement

None declared.