Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 May 1;16(5):682-687.
doi: 10.1123/ijspp.2020-0191. Epub 2021 Feb 4.

Effect of Acute Interset Foot Cooling on Lower Limb Strength Training Workout

Effect of Acute Interset Foot Cooling on Lower Limb Strength Training Workout

Zong-Yan Cai et al. Int J Sports Physiol Perform. .

Abstract

Purpose: The authors investigated the effect of foot cooling (FC) between sets in a leg press pyramid workout with resistance-trained participants.

Methods: A total of 12 resistance-trained men (age = 21.8 [0.6] y; training experience = 1.7 [1] y) performed a pyramid workout, including 4 sets of 85% to 90% 1-repetition maximum leg press exercise to exhaustion with interset FC or noncooling in a repeated-measures crossover design separated by 5 days. The authors immersed the participants' feet in 10°C water for 2.5 minutes between sets.

Results: Two-way repeated-measures analysis of variance revealed that FC elicited significantly higher repetitions and electromyography (EMG) values of the vastus lateralis (simple main effect of condition) than did noncooling (P < .05) in the second (repetitions: 11 [3.5] vs 7.75 [3.2]; EMG: 63.4% [19.4%] vs 54.5% [18.4%]), third (repetitions: 8.9 [3.2] vs 6.4 [2.1]; EMG: 71.5% [17.4%] vs 60.6% [19.4%]), and fourth (repetitions: 7.5 [2.7] vs 5.1 [2.2]; EMG: 75.2% [19.6%] vs 59.3% [23.5%]) sets. The authors also detected a simple main effect of set in the FC and noncooling conditions on repetitions (P < .05) and in the FC condition on the vastus lateralis EMG values. Although the authors observed no time × trial interactions for the rating of perceived exertion, the authors observed main effects on the sets (7.7-9.6 vs 7.9-9.3, P < .05).

Conclusions: Interset FC provides an ergogenic effect on a leg press pyramid workout and may offset fatigue, as indicated by higher repetitions and EMG response, without increasing perceived exertion.

Keywords: cold immersion; electromyography; leg press; pyramid workout.

PubMed Disclaimer

LinkOut - more resources