Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Mar 1;72(3):e71-e77.
doi: 10.1097/MPG.0000000000003004.

Relevance of Methane and Carbon Dioxide Evaluation in Breath Tests for Carbohydrate Malabsorption in a Paediatric Cohort

Affiliations

Relevance of Methane and Carbon Dioxide Evaluation in Breath Tests for Carbohydrate Malabsorption in a Paediatric Cohort

Karin Hammer et al. J Pediatr Gastroenterol Nutr. .

Abstract

Objectives: The relevance of methane measurement in breath tests for the detection of carbohydrate malabsorption in children is controversial. The need for correction for poor sample collection is disputed. We evaluated the relevance of methane/CO2 measurements for the diagnosis of paediatric carbohydrate malabsorption.

Methods: A total of 132 breath tests (fructose: n = 54; lactose: n = 78) were performed in 91 children/adolescents with functional abdominal complaints. Breath samples were collected and analysed for hydrogen, methane, and CO2. Malabsorption was defined by a net increase over baseline of ≥20 parts per million (ppm) for hydrogen, ≥5 to ≥12 ppm for methane, and ≥10 to ≥15 ppm for hydrogen-plus-methane. The diagnosis was made before and after the use of a CO2-based correction factor (5.5% as the numerator). Hydrogen-based test results were compared with results obtained with other cut-off values.

Results: Fifty-eight positive tests were obtained by hydrogen measurement (without CO2 correction). The addition of methane measurements did not significantly influence the test results (P > 0.05). Only under the use of extraordinary cut-offs (combined hydrogen-plus-methane smaller than ≥18 ppm) did the rate of malabsorbers increase significantly (P < 0.05). After CO2 correction, hydrogen ≥20 ppm was detected in 4 additional patients, but 1 patient lost the hydrogen-based diagnosis of malabsorption (Cohen kappa = 0.92).

Conclusions: Methane measurement did not significantly affect the detection rate of carbohydrate malabsorbers in children/adolescents with functional abdominal complaints when established cut-offs are used. The use of CO2 correction altered the diagnosis of malabsorption in a minority of patients but did not significantly alter overall test results.

PubMed Disclaimer

Conflict of interest statement

The authors report no conflicts of interest.

References

    1. Gasbarrini A, Corazza GR, Gasbarrini G, et al. 1st Rome H2-Breath Testing Consensus Conference Working Group. Methodology and indications of H2-breath testing in gastrointestinal diseases: the Rome Consensus Conference. Aliment Pharmacol Ther 2009; 29 Suppl 1:1–49.
    1. Rezaie A, Buresi M, Lembo A, et al. Hydrogen and methane-based breath testing in gastrointestinal disorders: the North American Consensus. Am J Gastroenterol 2017; 112:775–784.
    1. Levitt MD, Furne JK, Kuskowski M, et al. Stability of human methanogenic flora over 35 years and a review of insights obtained from breath methane measurements. Clin Gastroenterol Hepatol 2006; 4:123–129.
    1. Tormo R, Bertaccini A, Conde M, et al. Methane and hydrogen exhalation in normal children and in lactose malabsorption. Early Hum Dev 2001; 65 (Suppl):S165–S172.
    1. Medow MS, Glassman MS, Schwarz SM, et al. Respiratory methane excretion in children with lactose intolerance. Dig Dis Sci 1993; 38:328–332.