Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1988 Apr;70(4):491-9.

A comparison of primary and revision total knee arthroplasty using the kinematic stabilizer prosthesis

Affiliations
  • PMID: 3356715
Comparative Study

A comparison of primary and revision total knee arthroplasty using the kinematic stabilizer prosthesis

A D Hanssen et al. J Bone Joint Surg Am. 1988 Apr.

Abstract

The first 121 arthroplasties (in 105 patients) in which the cemented kinematic-stabilizer total knee prosthesis was used for primary arthroplasty or surgical revision at the Mayo Clinic were reviewed. Sixty-six patients (seventy-nine arthroplasties) were followed for a mean of thirty-seven months. There were fifty-three revision and twenty-six primary arthroplasties. The average range of motion in both groups increased from 95 to 101 degrees. Although none of these patients could ascend stairs without support before the operation, thirty-two (51 per cent) could do so at the time of the final follow-up. The incidence of moderate or severe pain was reduced from 86 to 6 per cent. Moderate or severe ligamentous instability had been present in thirty-three knees (42 per cent) preoperatively, but only five knees had significant medial, lateral, anterior, or posterior instability at final follow-up. The Hospital for Special Surgery knee score increased from an average of 56 points to 83 points in all of the knees. At follow-up, the patients who had had primary arthroplasty had 92 per cent good or excellent results and the patients who had had surgical revision had 81 per cent good or excellent results (p less than 0.05). There was no significant difference in the results between the patients who had osteoarthritis and those who had rheumatoid arthritis. Over-all, 85 per cent of the results were good or excellent at final follow-up. Tibial radiolucent lines of one to two millimeters were observed in 29 per cent of the knees at follow-up.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Publication types