Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Feb 11;49(5):566-571.
doi: 10.1515/jpm-2020-0169. Print 2021 Jun 25.

Comparison of maternal third trimester hemodynamics between singleton pregnancy and twin pregnancy

Affiliations

Comparison of maternal third trimester hemodynamics between singleton pregnancy and twin pregnancy

Romina-Marina Sima et al. J Perinat Med. .

Abstract

Objectives: The impedance cardiography (ICG) technique measures the variation of impedance in the thorax due to the physical contractile activity of the heart. Twin pregnancy is characterized by greater maternal hemodynamic changes than a singleton pregnancy.

Methods: In a study on 121 pregnant women in the last trimester we performed ICG, evaluating the following hemodynamic parameters: stroke volume, heart rate, cardiac output, ventricular ejection time, left ventricular ejection time, thoracic impedance, and systemic vascular resistance.

Results: The study included singleton and twin pregnancies. Heart rate values in women with single fetus was lower than in those carrying twins (85 vs. 100 beats/min, p=0.021) as were the stroke volume values (64 vs. 83 mL, p=0.010) and the cardiac output (p<0.0001). Systemic vascular resistance decreased in twin pregnancies compared to singleton pregnancy (p=0.023).

Conclusions: ICG studies are rare, and the validation of their results is an ongoing process. However, the ICG technique is applicable in the third trimester of pregnancy and can yield important information regarding the hemodynamic profile of singleton and twin pregnancies, revealing maternal heart changes specific to twin pregnancies.

Keywords: hemodynamic parameters; impedance cardiography; singleton pregnancy; twin pregnancy.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Robson, SC, Hunter, S, Boys, RJ, Dunlop, W. Serial study of factors influencing changes in cardiac output during human pregnancy. Am J Physiol 1989;256:H1060–5. https://doi.org/10.1152/ajpheart.1989.256.4.h1060.
    1. Hunter, S, Robson, SC. Adaptation of the maternal heart in pregnancy. Br Heart J 1992;68:540–3. https://doi.org/10.1136/hrt.68.12.540.
    1. Mabie, WC, DiSessa, TG, Crocker, LG, Sibai, BM, Arheart, KL. A longitudinal study of cardiac output in normal human pregnancy. Am J Obstet Gynecol 1994;170:849–56. https://doi.org/10.1016/s0002-9378(94)70297-7.
    1. Duvekot, JJ, Peeters, LL. Maternal cardiovascular hemodynamic adaptation to pregnancy. Obstet Gynecol Surv 1994;49:S1–14. https://doi.org/10.1097/00006254-199412011-00001.
    1. Kametas, NA, McAuliffe, F, Krampl, E, Chambers, J, Nicolaides, KH. Maternal cardiac function in twin pregnancy. Obstet Gynecol 2003;102:806–15. https://doi.org/10.1097/00006250-200310000-00024.

LinkOut - more resources