Comparison of the visual performance between Oculentis MF30 and Tecnis ZMB00 multifocal intraocular lenses
- PMID: 33569446
- PMCID: PMC7867926
- DOI: 10.21037/atm-20-7777
Comparison of the visual performance between Oculentis MF30 and Tecnis ZMB00 multifocal intraocular lenses
Abstract
Background: To compare the visual performance of MF30 asymmetric refractive multifocal intraocular lenses (MIOLs) with ZMB00 all optic zone diffractive MIOLs.
Methods: This is a prospective study. Patients that underwent phacoemulsification were divided into two groups according to the type of MIOLs used: 35 patients were implanted with asymmetric refractive MIOLs and 35 patients with all optic zone diffractive MIOLs. Visual acuity (VA), refraction, defocus curves, objective optical quality, and a questionnaire evaluating quality of life were measured at 3 months postoperatively.
Results: There were no significant differences between the two groups in uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), best-corrected distance visual acuity (BCDVA), or distance-corrected near visual acuity (DCNVA). However, the uncorrected intermediate VA was 0.24±0.10 in the refractive group and 0.31±0.13 in the diffractive group (P<0.05), and the distance-corrected intermediate VA was 0.22±0.09 in the refractive group and 0.31±0.14 in the diffractive group (P<0.05). Defocus curves showed two peaks of maximum vision in both groups. However, the curve between the two peaks in the refractive group was smoother than that of the diffractive group. The modulated transfer function cut-off frequency was 22.74±12.29 c/d in the refractive group and 30.50±10.04 c/d in the diffractive group (P<0.05). The Optical Quality Analysis System (OQAS) values 100% (OV100%) was 0.75±0.41 in the refractive group and 1.02±0.34 in the diffractive group (P<0.05), while the OV20% was 0.52±0.34 in the refractive group and 0.71±0.25 in the diffractive group (P<0.05). There was no significant difference between the two groups in overall satisfaction, spectacle independence ratio, or visual interference phenomenon.
Conclusions: Both MIOLs achieve good VA at distance and near vision. Oculentis MF30 showed better intermediate VA, and Tecnis ZMB00 appears to have better objective visual quality.
Trial registration: NCT02234635 (http://www.clinicaltrials.gov).
Keywords: Asymmetric; diffractive; multifocal intraocular lens; refractive; visual quality.