. 2021 Jun 14;59(6):1155-1163.
doi: 10.1093/ejcts/ezab018.

Five-year outcomes of patients supported with HeartMate 3: a single-centre experience

Affiliations

Five-year outcomes of patients supported with HeartMate 3: a single-centre experience

Jan D Schmitto et al. Eur J Cardiothorac Surg. .

Abstract

Objectives: The HeartMate 3 left ventricular assist device was first implanted in 2014 and received the Conformité Européenne mark in 2015. Since then, several trials demonstrated its high haemocompatibility associated with good survival and low adverse events rates. Herein, we report our institutional experience with patients supported with HeartMate 3 for 5 years.

Methods: This prospective cohort study included patients receiving a HeartMate 3 implantation in 2014 as part of the HeartMate 3 Conformité Européenne Mark clinical trial. Patients had follow-up visits every 3 months while on left ventricular assist device support, and all patients completed the 5-year follow-up. The primary end point was survival at 5 years. Secondary end points included adverse events, health status and quality of life.

Results: Eight patients (men: 75%) aged 59 years (min-max: 52-66 years) were enrolled. At 5 years, survival was 100%. Patients remained on support for a median time of 1825 days (min-max: 101-1825 days); 2 patients successfully received cardiac transplants. No right heart failure, haemolysis, pump thrombosis, pump malfunction or neurological events occurred in any patients. A driveline infection was observed in 6 patients (0.25 events/patient-year). Compared to baseline, a significant improvement in quality of life and in New York Heart Association functional class was noted after the implant and for the whole follow-up time. A slight decline in kidney function and in the 6-min walk test results occurred after 3 years.

Conclusions: This study reports the longest single-centre follow-up of the HeartMate 3, showing excellent haemocompatibility over time with high survival and low complication rates at 5 years.

Keywords: Heart failure; HeartMate 3; Left ventricular assist device; Mechanical circulatory support.