Periprosthetic occult acetabular fracture: an unknown side effect of press-fit techniques in primary cementless total hip arthroplasty
- PMID: 33585969
- DOI: 10.1007/s00590-021-02894-5
Periprosthetic occult acetabular fracture: an unknown side effect of press-fit techniques in primary cementless total hip arthroplasty
Abstract
Background: This study sought to investigate the prevalence and risk factors of periprosthetic occult acetabular fracture occurring during cementless acetabular cup insertion in patients undergoing primary total hip arthroplasty (THA) and to assess the clinical consequences of these fractures.
Methods: A total of 232 hips (n = 205 patients) were included in this study. A periprosthetic occult acetabular fracture was defined as that which was unrecognised intraoperatively and was undetectable on post-operative radiographs yet was successfully diagnosed on post-operative computed tomography (CT) images. Clinical (age, sex, body mass index, and preoperative diagnosis) and surgical (additional screw fixation, cup rim size, and cup type) variables were analysed to identify risk factors for periprosthetic occult acetabular fracture.
Results: Sixteen (6.9%) periprosthetic occult intraoperative acetabular fractures were identified. In addition, one (0.4%) periprosthetic acetabular fracture was found during operation. The superolateral wall (9/16 hips; 56.3%) was the most frequent location. In addition, one (0.4%) periprosthetic acetabular fracture was found during operation. Male sex was the only factor associated with an increased risk for periprosthetic occult intraoperative acetabular fracture (odds ratio for male versus female sex: 4.28; p = 0.04). There was no significant association between cup type and the occurrence of periprosthetic occult acetabular fracture. All 16 hips with periprosthetic occult intraoperative acetabular fracture were healed at the final follow-up visit without the requirement for any additional surgical interventions.
Conclusion: The results of the current study suggest that periprosthetic occult acetabular fractures are common during press-fit acetabular cup insertion in primary THA. Surgeons should have a high index of suspicion and early CT imaging referral in male patients who present with unexplained early post-operative groin pain in primary THA using cementless acetabular cups.
Keywords: Acetabular fracture; Occult fracture; Periprosthetic fracture; Press-fit fixation; Total hip arthroplasty.
© 2021. The Author(s), under exclusive licence to Springer-Verlag France SAS part of Springer Nature.
Similar articles
-
Incidence and outcomes of intraoperative periprosthetic acetabular fractures during cementless total hip arthroplasty: a prospective three-dimensional computer tomography-based study.Int Orthop. 2024 Mar;48(3):667-674. doi: 10.1007/s00264-023-05988-3. Epub 2023 Sep 19. Int Orthop. 2024. PMID: 37723316
-
Periprosthetic Occult Fractures of the Acetabulum Occur Frequently During Primary THA.Clin Orthop Relat Res. 2017 Feb;475(2):484-494. doi: 10.1007/s11999-016-5138-z. Epub 2016 Oct 31. Clin Orthop Relat Res. 2017. PMID: 27800574 Free PMC article.
-
Occult intra-operative periprosthetic fractures of the acetabulum may affect implant survival.Int Orthop. 2019 Jul;43(7):1583-1590. doi: 10.1007/s00264-018-4084-7. Epub 2018 Aug 10. Int Orthop. 2019. PMID: 30097730
-
Periprosthetic acetabular fractures.Orthop Traumatol Surg Res. 2025 Feb;111(1S):104068. doi: 10.1016/j.otsr.2024.104068. Epub 2024 Nov 22. Orthop Traumatol Surg Res. 2025. PMID: 39581492 Review.
-
[Periprosthetic fractures of the acetabulum: osteosynthesis].Chirurg. 2020 Oct;91(10):813-822. doi: 10.1007/s00104-020-01228-1. Chirurg. 2020. PMID: 32617613 Review. German.
Cited by
-
Incidence and outcomes of intraoperative periprosthetic acetabular fractures during cementless total hip arthroplasty: a prospective three-dimensional computer tomography-based study.Int Orthop. 2024 Mar;48(3):667-674. doi: 10.1007/s00264-023-05988-3. Epub 2023 Sep 19. Int Orthop. 2024. PMID: 37723316
-
Relationship Between Acetabular Hounsfield Unit Values and Periprosthetic Fractures in Cementless Total Hip Arthroplasty: A Matched Case-Control Study.Arthroplast Today. 2022 Jan 17;14:216-222.e1. doi: 10.1016/j.artd.2021.11.016. eCollection 2022 Apr. Arthroplast Today. 2022. PMID: 35510068 Free PMC article.
-
Vibratory and conventional impaction of acetabular components into porcine acetabula.Bone Joint Res. 2025 Apr 7;14(4):309-317. doi: 10.1302/2046-3758.144.BJR-2024-0068.R2. Bone Joint Res. 2025. PMID: 40189212 Free PMC article.
-
Combined direct anterior approach and navigation-assisted percutaneous anterograde posterior column fixation for acetabular periprosthetic fractures.Oper Orthop Traumatol. 2025 May 7. doi: 10.1007/s00064-025-00900-1. Online ahead of print. Oper Orthop Traumatol. 2025. PMID: 40332603 Review. English.
-
[Periprosthetic fracture in hip replacement-risk factors and treatment].Orthopadie (Heidelb). 2025 Jul;54(7):522-529. doi: 10.1007/s00132-025-04658-z. Epub 2025 May 21. Orthopadie (Heidelb). 2025. PMID: 40399567 Free PMC article. German.
References
-
- Davidson D, Pike J, Garbuz D, Duncan CP, Masri BA (2008) Intraoperative periprosthetic fractures during total hip arthroplasty. Evaluation and management. J Bone Joint Surg Am 90:2000–2012 - DOI
-
- Yun HH, Lim JT, Yang SH, Park PS (2019) Occult periprosthetic femoral fractures occur frequently during a long, trapezoidal, double-tapered cementless femoral stem fixation in primary THA. PLoS ONE 14:e0221731 - DOI
-
- Olory B, Havet E, Gabrion A, Vernois J, Mertl P (2004) Comparative in vitro assessment of the primary stability of cementless press-fit acetabular cups. Acta Orthop Belg 70(1):31–37 - PubMed
-
- Antoniades G, Smith EJ, Deakin AH, Wearing SC, Sarungi M (2013) Primary stability of two uncementedacetabular components of different geometry: hemispherical or peripherallyenhanced? Bone Joint Res 2(12):264–269 - DOI
-
- Abdel MP, Houdek MT, Watts CD, Lewallen DG, Berry DJ (2016) Epidemiology of periprosthetic femoral fractures in 5417 revision total hip arthroplasties: a 40-year experience. Bone Joint J 98:468–474 - DOI