Energy, current, and success in defibrillation and cardioversion: clinical studies using an automated impedance-based method of energy adjustment
- PMID: 3359585
- DOI: 10.1161/01.cir.77.5.1038
Energy, current, and success in defibrillation and cardioversion: clinical studies using an automated impedance-based method of energy adjustment
Abstract
The purposes of this study were two. First, we wanted to evaluate in patients a technique for automated adjustment of selected energy for defibrillation or cardioversion based on transthoracic impedance. Second, we wanted to define the relationship of peak current and shock success in various arrhythmias. Applying a previously validated method of predicting transthoracic impedance in advance of any shock, we modified defibrillators to automatically double the operator-selected energy if the predicted impedance exceeded 70 omega. Success rates of shocks given for ventricular and atrial arrhythmias from these modified energy-adjusting defibrillators were compared with success rates for shocks given from standard defibrillators. We prospectively collected data on 347 patients who received a total of 1009 shocks. Low-energy (100 J) shocks given to high-impedance (greater than or equal to 70 omega) patients had a poor success rate; in such high-impedance patients significant improvement in shock success rate was achieved by the energy-adjusting defibrillators. For example, when 100 J shocks were selected for high-impedance patients in ventricular fibrillation the energy-adjusting defibrillators achieved a shock success rate of 75%, whereas standard defibrillators achieved a shock success rate of only 36% (p less than .01). Similar improvements were seen for ventricular tachycardia and atrial fibrillation. Thus, automated energy adjustment based on transthoracic impedance is a beneficial approach to defibrillation and cardioversion. For ventricular fibrillation, atrial fibrillation, and atrial flutter there was a clear relationship between peak current and shock success.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Advance prediction of transthoracic impedance in human defibrillation and cardioversion: importance of impedance in determining the success of low-energy shocks.Circulation. 1984 Aug;70(2):303-8. doi: 10.1161/01.cir.70.2.303. Circulation. 1984. PMID: 6733884
-
Determinants of successful transthoracic defibrillation and outcome in ventricular fibrillation.Br Heart J. 1991 Jun;65(6):311-6. doi: 10.1136/hrt.65.6.311. Br Heart J. 1991. PMID: 2054239 Free PMC article.
-
Factors determining success and energy requirements for cardioversion of atrial fibrillation.Q J Med. 1990 Sep;76(281):903-13. Q J Med. 1990. PMID: 2236476
-
Electrical therapy for cardiovascular emergencies.Circulation. 1986 Dec;74(6 Pt 2):IV111-6. Circulation. 1986. PMID: 3536157 Review.
-
Transthoracic cardioversion of atrial fibrillation and flutter: standard techniques and new advances.Am J Cardiol. 1996 Oct 17;78(8A):22-6. doi: 10.1016/s0002-9149(96)00562-0. Am J Cardiol. 1996. PMID: 8903272 Review.
Cited by
-
[Transthoracic defibrillation. Physiologic and pathophysiologic principles and their role in the outcome of resuscitation].Anaesthesist. 2004 Feb;53(2):125-36. doi: 10.1007/s00101-003-0635-3. Anaesthesist. 2004. PMID: 14991189 Review. German.
-
First-time evaluation of ascending compared to rectangular transthoracic defibrillation waveforms in modelled out-of-hospital cardiac arrest.Resusc Plus. 2020 Jun 1;1-2:100006. doi: 10.1016/j.resplu.2020.100006. eCollection 2020 Mar-Jun. Resusc Plus. 2020. PMID: 34223293 Free PMC article.
-
Role of peak current in conversion of patients with ventricular fibrillation.Singapore Med J. 2017 Jul;58(7):432-437. doi: 10.11622/smedj.2017070. Singapore Med J. 2017. PMID: 28741007 Free PMC article. Clinical Trial.
-
Hands-on defibrillation has the potential to improve the quality of cardiopulmonary resuscitation and is safe for rescuers-a preclinical study.J Am Heart Assoc. 2012 Oct;1(5):e001313. doi: 10.1161/JAHA.112.001313. Epub 2012 Oct 25. J Am Heart Assoc. 2012. PMID: 23316286 Free PMC article.
-
Towards Low Energy Atrial Defibrillation.Sensors (Basel). 2015 Sep 3;15(9):22378-400. doi: 10.3390/s150922378. Sensors (Basel). 2015. PMID: 26404298 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources