Functional Hemodynamic Monitoring With a Wireless Ultrasound Patch

Affiliations
Free article
Review

Functional Hemodynamic Monitoring With a Wireless Ultrasound Patch

Jon-Émile S Kenny. J Cardiothorac Vasc Anesth. 2021 May.
Free article

Abstract

In this Emerging Technology Review, a novel, wireless, wearable Doppler ultrasound patch is described as a tool for resuscitation. The device is designed, foremost, as a functional hemodynamic monitor-a simple, fast, and consistent method for measuring hemodynamic change with preload variation. More generally, functional hemodynamic monitoring is a paradigm that helps predict stroke volume response to additional intravenous volume. Because Doppler ultrasound of the left ventricular outflow tract noninvasively measures stroke volume in realtime, it increasingly is deployed for this purpose. Nevertheless, Doppler ultrasound in this manner is cumbersome, especially when repeat assessments are needed. Accordingly, peripheral arteries have been studied and various measures from the common carotid artery Doppler signal act as windows to the left ventricle. Yet, handheld Doppler ultrasound of a peripheral artery is susceptible to human measurement error and statistical limitations from inadequate beat sample size. Therefore, a wearable Doppler ultrasound capable of continuous assessment minimizes measurement inconsistencies and smooths inherent physiologic variation by sampling many more cardiac cycles. Reaffirming clinical studies, the ultrasound patch tracks immediate SV change with excellent accuracy in healthy volunteers when cardiac preload is altered by various maneuvers. The wearable ultrasound also follows jugular venous Doppler, which qualitatively trends right atrial pressure. With further clinical research and the application of artificial intelligence, the monitoring modalities with this new technology are manifold.

Keywords: carotid Doppler; corrected flow time; functional hemodynamic monitoring; velocity time integral; volume responsiveness; wearable technology.