Bioimpedance analysis as a tool for hemodynamic monitoring: overview, methods and challenges
- PMID: 33607637
- DOI: 10.1088/1361-6579/abe80e
Bioimpedance analysis as a tool for hemodynamic monitoring: overview, methods and challenges
Abstract
Recent advances in hemodynamic monitoring have seen the advent of non-invasive methods which offer ease of application and improve patient comfort. Bioimpedance Analysis or BIA is one of the currently employed non-invasive techniques for hemodynamic monitoring. Impedance Cardiography (ICG), one of the implementations of BIA, is widely used as a non-invasive procedure for estimating hemodynamic parameters such as stroke volume (SV) and cardiac output (CO). Even though BIA is not a new diagnostic technique, it has failed to gain consensus as a reliable measure of hemodynamic parameters. Several devices have emerged for estimating CO using ICG which are based on evolving methodologies and techniques to calculate SV. However, the calculations are generally dependent on the electrode configurations (whole body, segmental or localised) as well as the accuracy of different techniques in tracking blood flow changes. Blood volume changes, concentration of red blood cells, pulsatile velocity profile and ambient temperature contribute to the overall conductivity of blood and hence its impedance response during flow. There is a growing interest in investigating limbs for localised BIA to estimate hemodynamic parameters such as pulse wave velocity. As such, this paper summarises the current state of hemodynamic monitoring through BIA in terms of different configurations and devices in the market. The conductivity of blood flow has been emphasized with contributions from both volume and velocity changes during flow. Recommendations for using BIA in hemodynamic monitoring have been mentioned highlighting the suitable range of frequencies (1 kHz-1 MHz) as well as safety considerations for a BIA setup. Finally, current challenges in using BIA such as geometry assumption and inaccuracies have been discussed while mentioning potential advantages of a multi-frequency analysis to cover all the major contributors to blood's impedance response during flow.
Keywords: bioimpedance; blood; hemodynamics.
© 2021 Institute of Physics and Engineering in Medicine.
Similar articles
-
[Clinical application of the electric cardiometry based non-invasive ICON® hemodynamic monitor].Orv Hetil. 2018 Nov;159(44):1775-1781. doi: 10.1556/650.2018.31225. Orv Hetil. 2018. PMID: 30392409 Review. Hungarian.
-
[Design and Implementation of Non-Invasive Hemodynamic Monitoring System Based on Impedance Cardiogram Method].Zhongguo Yi Liao Qi Xie Za Zhi. 2025 Jan 30;49(1):80-88. doi: 10.12455/j.issn.1671-7104.240364. Zhongguo Yi Liao Qi Xie Za Zhi. 2025. PMID: 39993986 Chinese.
-
Continuous non-invasive measurement of stroke volume and cardiac index in infants and children: comparison of Impedance Cardiography NICaS® vs CardioQ® method.Clin Ter. 2018 May-Jun;169(3):e110-e113. doi: 10.7417/T.2018.2064. Clin Ter. 2018. PMID: 29938742
-
Incorporating pulse wave velocity into model-based pulse contour analysis method for estimation of cardiac stroke volume.Comput Methods Programs Biomed. 2020 Oct;195:105553. doi: 10.1016/j.cmpb.2020.105553. Epub 2020 May 26. Comput Methods Programs Biomed. 2020. PMID: 32497771
-
Bench to bedside: electrophysiologic and clinical principles of noninvasive hemodynamic monitoring using impedance cardiography.Acad Emerg Med. 2003 Jun;10(6):669-80. doi: 10.1111/j.1553-2712.2003.tb00054.x. Acad Emerg Med. 2003. PMID: 12782531 Review.
Cited by
-
Design and Manufacturing of Equipment for Investigation of Low Frequency Bioimpedance.Micromachines (Basel). 2022 Oct 29;13(11):1858. doi: 10.3390/mi13111858. Micromachines (Basel). 2022. PMID: 36363879 Free PMC article.
-
Determination of the Geometric Parameters of Electrode Systems for Electrical Impedance Myography: A Preliminary Study.Sensors (Basel). 2021 Dec 24;22(1):97. doi: 10.3390/s22010097. Sensors (Basel). 2021. PMID: 35009640 Free PMC article.
-
Establishment and analysis of the prediction model for the prognosis of children with sepsis based on pSOFA score.Pak J Med Sci. 2025 Apr;41(4):1126-1131. doi: 10.12669/pjms.41.4.10001. Pak J Med Sci. 2025. PMID: 40290256 Free PMC article.
-
Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis.Sensors (Basel). 2022 Jun 23;22(13):4736. doi: 10.3390/s22134736. Sensors (Basel). 2022. PMID: 35808233 Free PMC article.
-
The Effect of Increasing the Body's Core Temperature and Improving Blood Flow by Using Far-Infrared Rays Emitted from Functional Loess Bio-Balls.Biomedicines. 2024 Dec 23;12(12):2922. doi: 10.3390/biomedicines12122922. Biomedicines. 2024. PMID: 39767828 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials