Design of assessment tool for unplanned endotracheal extubation of artificial airway patients
- PMID: 33616306
- PMCID: PMC8186713
- DOI: 10.1002/nop2.807
Design of assessment tool for unplanned endotracheal extubation of artificial airway patients
Abstract
Aim: Unplanned endotracheal extubation (UEE) is one of the most common adverse events reported in patients with artificial airway. Current research in UEE is mostly limited to the summary of risk factors and analysis of prevention strategies. The aim of the study was to develop an assessment tool for medical staff to assess the risk of unplanned extubation in endotracheal intubation patients.
Design: The design was a qualitative study.
Methods: Based on literature review, group discussion, pre-investigation, the initial risk assessment scale on unplanned extubation for endotracheal intubation patients was established. Fifteen experts from thirteen tertiary-A hospitals across eight provinces participated in two rounds of Delphi panel.
Results: The risk assessment tool on unplanned extubation for endotracheal intubation patients was established by the Delphi method. It was composed of 11 indicators, which got agreement among two rounds panel.
Keywords: Delphi method; endotracheal intubation; risk assessment tool; unplanned extubation.
© 2021 The Authors. Nursing Open published by John Wiley & Sons Ltd.
Conflict of interest statement
The authors declare that they have no conflicts of interest.
References
-
- Ben, D. F. , Lu, K. Y. , Chen, X. L. , Yu, X. Y. , Xi, H. J. , Chang, F. , Zhu, S. H. , Tang, H. T. , Wei, L. , Ma, B. & Xia, Z. F. (2011). Unplanned decannulation of tracheotomy tube in massive burn patients: A retrospective case series study. The Chinese Medical Journal (England), 124(20), 3309–3313.Retrieved from https://www.ncbi.nlm.nih.gov/pubmed/22088527 - PubMed
-
- Buckley, J. C. , Brown, A. P. , Shin, J. S. , Rogers, K. M. , & Hoftman, N. N. (2016). A comparison of the haider tube‐guard(R) endotracheal tube holder versus adhesive tape to determine if this novel device can reduce endotracheal tube movement and prevent unplanned extubation. Anesthesia and Analgesia, 122(5), 1439–1443. 10.1213/ANE.0000000000001222 - DOI - PMC - PubMed
-
- Chang, L. C. , Liu, P. F. , Huang, Y. L. , Yang, S. S. , & Chang, W. Y. (2011). Risk factors associated with unplanned endotracheal self‐extubation of hospitalized intubated patients: A 3‐year retrospective case‐control study. Applied Nursing Research, 24(3), 188–192. 10.1016/j.apnr.2009.09.002 - DOI - PubMed