Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Nov;74(5):1752-1762.e1.
doi: 10.1016/j.jvs.2021.01.064. Epub 2021 Feb 19.

A systematic review on endovascular repair of isolated common iliac artery aneurysms and suggestions regarding diameter thresholds for intervention

Affiliations
Free article

A systematic review on endovascular repair of isolated common iliac artery aneurysms and suggestions regarding diameter thresholds for intervention

Nektarios Charisis et al. J Vasc Surg. 2021 Nov.
Free article

Abstract

Objective: Our aim was to systematically review results of endovascular aneurysm repair for isolated common iliac artery aneurysms (CIAA) regarding outcomes and to determine if changes should be made to current diameter threshold recommendations for intervention.

Methods: A comprehensive systematic review was performed according to the PRISMA guidelines. PubMed, Scopus, and the Cochrane Central databases were searched.

Results: Twenty-one studies were deemed eligible and provided data for 879 patients and 981 isolated CIAA treated with endovascular repair. The majority of the patients (90.8%) were males. The weighted mean age of the patients was 71.7 years (range, 37-91 years). The weighted mean diameter for the CIAA was 41. mm 1 (range, 15-110 mm) and for ruptured aneurysms 58.4 mm. The overall technical success rate was 97.6%. The perioperative mortality rate was 0.7%. Secondary patency rates were reported in only four studies and varied between 96.7% and 100%. The overall morbidity rate was 14%, ranging from 0% to 25%. Most of the studies did not report long-term or adequate follow-up data. Rupture of an isolated CIAA at <4 cm diameter was extremely low.

Conclusions: Endovascular treatment of isolated CIAA is feasible and safe with a low mortality and excellent technical success rates. Consideration of increasing the diameter threshold for intervention of CIAA to 4 cm should be considered. Studies with longer follow-up and reliable long-term results are needed.

Keywords: Common iliac artery aneurysm; Diameter threshold; Endovascular repair; Systematic review.