Utility of transesophageal echocardiography to assess real time left atrial pressure changes and dynamic mitral regurgitation following placement of transseptal multistage venous cannula for systemic venous drainage and indirect left ventricular venting in venoarterial extracorporeal membrane oxygenation
- PMID: 33619808
- DOI: 10.1111/echo.14990
Utility of transesophageal echocardiography to assess real time left atrial pressure changes and dynamic mitral regurgitation following placement of transseptal multistage venous cannula for systemic venous drainage and indirect left ventricular venting in venoarterial extracorporeal membrane oxygenation
Abstract
A patient with heart failure due to nonischemic cardiomyopathy presented as a transfer to our institution following peripheral (femoral) venoarterial (VA) extracorporeal membrane oxygenation (ECMO) placement. With peripheral VA ECMO cannulation, the patient continued to have unstable ventricular tachyarrhythmias. Echocardiography demonstrated left ventricular (LV) dilation and severe mitral regurgitation (MR) with clinical and chest X-ray evidence of pulmonary edema. To provide venous drainage and simultaneous decompression of the left atrium (LA) and thereby indirect LV venting, a single multistage venous cannula was placed across the inter-atrial septum (IAS) using the previously described left atrial venoarterial (LA-VA) ECMO cannulation technique. Two- and three-dimensional (3D) transesophageal echocardiography (TEE) demonstrated utility in guiding cannula placement into the appropriate position and providing real time assessment of ventricular decompression and MR severity. There was subsequent improvement in pulmonary edema. This case is thought to be the first demonstration of real time resolution of pulmonary venous flow reversal in a patient undergoing LA-VA ECMO cannulation. This demonstration offers important mechanistic insight into some of the potential benefits of such an approach.
Keywords: ECMO; extracorporeal membranous oxygenation; left atrial pressure; mechanical circulatory support; mitral regurgitation; three-dimensional echocardiography; transseptal cannulation.
© 2021 Wiley Periodicals LLC.
References
REFERENCES
-
- Dulnuan K, Guglin M, Zwischenberger J, et al. Left atrial veno-arterial extracorporeal membrane oxygenation: percutaneous bi-atrial drainage to avoid pulmonary edema in patients with left ventricular systolic dysfunction. J Am Coll Cardiol. 2018;71(11 Supplement):A1358.
-
- Whiteside HL, Hillerson D, Coots RD, et al. Safety and efficacy of left atrial veno-arterial (LAVA) extracorporeal membrane oxygenation for the management of cardiogenic shock. Poster presented at: The Society for Cardiovascular Angiography and Interventions (SCAI) 2020 Scientific Sessions; March 14-16, 2020; Virtual Conference.
-
- Addis DR, Wang B, Prejean SP, Watts TE 3rd, Nanda NC, Ahmed MI. Utility of three-dimensional transesophageal echocardiography to guide transseptal positioning of a single multistage venous cannula to provide both venous drainage and indirect left ventricular venting in veno-arterial extracorporeal membrane oxygenation. Echocardiography. 2020;;37(11):1860-1863.
-
- Tabata T, Thomas JD, Klein AL. Pulmonary venous flow by doppler echocardiography: revisited 12 years later. J Am Coll Cardiol. 2003;41(8):1243-1250.
-
- Klein AL, Stewart WJ, Bartlett J, et al. Effects of mitral regurgitation on pulmonary venous flow and left atrial pressure: an intraoperative transesophageal echocardiographic study. J Am Coll Cardiol. 1992;20(6):1345-1352.
Publication types