Assessment of the reliability of hand-held surface scanner in the evaluation of adolescent idiopathic scoliosis
- PMID: 33625577
- DOI: 10.1007/s00586-021-06769-5
Assessment of the reliability of hand-held surface scanner in the evaluation of adolescent idiopathic scoliosis
Abstract
Purpose: Spinal deformities due to adolescent idiopathic scoliosis (AIS) result in impairment in the back surface topography. Sophisticated interventions are needed that address different aspects of deformity. The purpose of our study is to test the reliability of hand-held 3D scanners on the assessment of AIS.
Methods: Forty-two AIS patients were included in our study. The back surfaces of the patients were scanned with the hand-held 3D scanner, while the patients were in the standing position with the arms hanging at the sides (P1), with the arms extended (P2), and forward bending position (P3). The acquired original image was superimposed with the mirror image. Root mean square (RMS) of the point-to-point distance was calculated, and the differences between the surfaces were determined. Correlation between RMS, Cobb, POTSI, scoliometer, radiographic rotations, TRACE results was calculated.
Results: A significant correlation coefficency (r) was found between the RMS and Cobb values in the thoracic (P1 = 0.80, P2 = 0.76, P3 = 0.71) and lumbal region (P1 = 0.56, P2 = 0.65, P3 = 0.63); between RMS and Raimondi in the thoracic (r, P1 = 0.80, P2 = 0.81, P3 = 0.78) and lumbar regions (P1 = 0.54, P2 = 0.64, P3 = 0.59); between RMS and scoliometer measurements in the thoracic (r, P1 = 0.58, P2 = 0.50, P3 = 0.41) and lumbar regions (P1 = 0.35, P2 = 0.41, P3 = 0.59); in thoracolumbar region between RMS and POTSI (P1 = 0.50, P2 = 0.25, P3= 0.36), between RMS and TRACE (P1 = 0.68, P2 = 0.5, P3 = 0.52), CONCLUSION: The hand-held scanners may contribute to gaining new insight into diagnosis and follow-up of AIS by its mobility that enables the acquisition of data in desired body position and place such as bedside or our patient clinics.
Level of evidence iv: Diagnostic: individual cross-sectional studies with consistently applied reference standard and blinding.
Keywords: 3D surface analyzes; Adolescent idiopathic scoliosis; Cobb; POTSI; Scoliometer.
© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH, DE part of Springer Nature.
References
-
- Morrissy RT, Goldsmith GS, Hall EC, Kehl D, Cowie GH (1990) Measurement of the Cobb angle on radiographs of patients who have scoliosis. Evaluation of intrinsic error. J Bone Joint Surg Am 72:320–327 - DOI
-
- Thulbourne T, Gillespie R (1976) The rib hump in idiopathic scoliosis. Measurement, analysis and response to treatment. J Bone Joint Surg Br 58:64–71 - DOI
-
- Kluba T, Schafer J, Hahnfeldt T, Niemeyer T (2006) Prospective randomized comparison of radiation exposure from full spine radiographs obtained in three different techniques. Eur Spine J 15:752–756. https://doi.org/10.1007/s00586-005-1005-4 - DOI - PubMed - PMC
-
- Coelho DM, Bonagamba GH, Oliveira AS (2013) Scoliometer measurements of patients with idiopathic scoliosis. Braz J PhysTher 17:179–184. https://doi.org/10.1590/S1413-35552012005000081 - DOI
-
- Weiss HR (1995) Measurement of vertebral rotation: Perdriolle versus Raimondi. Eur Spine J 4:34–38. https://doi.org/10.1007/BF00298416 - DOI - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical