Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2021 Mar 1;67(3):254-262.
doi: 10.1097/MAT.0000000000001380.

Viscoelastic Coagulation Monitor as a Novel Device to Assess Coagulation at the Bedside. A Single-Center Experience During the COVID-19 Pandemic

Affiliations
Observational Study

Viscoelastic Coagulation Monitor as a Novel Device to Assess Coagulation at the Bedside. A Single-Center Experience During the COVID-19 Pandemic

Mauro Panigada et al. ASAIO J. .

Abstract

Viscoelastic coagulation monitor (VCM) is a portable device developed to evaluate the viscoelastic properties of whole blood activated by contact with glass. In this study, VCM was employed to analyze the viscoelastic profiles of 36 COVID-19 intensive care patients. Full anticoagulant dose heparin (unfractionated [UFH]; low molecular weight [LMWH]) was administrated to all patients. The association between VCM and laboratory parameters was retrospectively analyzed. The administration of UFH-influenced VCM parameters prolonging clotting time (CT) and clot formation time (CFT) and reducing angle (alpha) and amplitudes of the VCM tracings (A10, A20, and maximum clot firmness [MCF]) compared with LMWH therapy. A tendency toward hypercoagulation was observed by short CT and CFT in patients receiving LMWH. Clotting time was correlated with UFH dose (Spearman's rho = 0.48, p ≤ 0.001), and no correlation was found between CT and LMWH. All VCM tracings failed to show lysis at 30 and 45 minutes, indicating the absence of fibrinolysis. A10, A20, and MCF exhibited very-good to good diagnostic accuracy for detecting platelet count and fibrinogen above the upper reference limit of the laboratory. In conclusion, VCM provided reliable results in COVID-19 patients and was easy to perform with minimal training at the bedside.

PubMed Disclaimer

Conflict of interest statement

Disclosure: Dr. Dalton is a consultant for Innovative ECMO Concepts. The other authors have no conflicts of interest to report.

References

    1. Whiting D, DiNardo JA. TEG and ROTEM: Technology and clinical applications. Am J Hematol. 2014; 89:228–232
    1. Ganter MT, Hofer CK. Coagulation monitoring: Current techniques and clinical use of viscoelastic point-of-care coagulation devices. Anesth Analg. 2008; 106:1366–1375
    1. Wikkelsø A, Wetterslev J, Møller AM, Afshari A. Thromboelastography (TEG) or rotational thromboelastometry (ROTEM) to monitor haemostatic treatment in bleeding patients: A systematic review with meta-analysis and trial sequential analysis. Anaesthesia. 2017; 72:519–531
    1. Amgalan A, Allen T, Othman M, Ahmadzia HK. Systematic review of viscoelastic testing (TEG/ROTEM) in obstetrics and recommendations from the women’s SSC of the ISTH. J Thromb Haemost. 2020; 18:1813–1838
    1. Schmidt AE, Israel AK, Refaai MA. The utility of thromboelastography to guide blood product transfusion. Am J Clin Pathol. 2019; 152:407–422

Publication types

LinkOut - more resources