Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2021 Feb;8(1):e000553.
doi: 10.1136/bmjgast-2020-000553.

Accuracy and comparison of two rapid multiplex PCR tests for gastroenteritis pathogens: a systematic review and meta-analysis

Affiliations
Meta-Analysis

Accuracy and comparison of two rapid multiplex PCR tests for gastroenteritis pathogens: a systematic review and meta-analysis

Li-Jun Chang et al. BMJ Open Gastroenterol. 2021 Feb.

Abstract

Objectives: The primary aim is to provide a summary of evidence for the diagnostic accuracies of multiplex PCR gastrointestinal (GI) panels-BioFire FilmArray and Luminex xTAG on the detection of gastroenteritis pathogens. The secondary aim is to compare the performance of these GI panels head to head.

Methods: A comprehensive search up to 1 December 2019 was conducted on PubMed, Embase, Ovid Medline and Web of Science for studies that used FilmArray or Luminex xTAG Gastrointestinal Pathogen Panel (GPP) for diagnosis of acute gastroenteritis. A summary of diagnostic accuracies for the 16 pathogens were calculated by comparing the GI panels to the current gold standards (conventional standard microbiology techniques such as culture or PCR for bacteria, PCR or enzyme immunoassay (EIA) for viruses, microscopy or EIA for parasite). Hierarchical summary receiver operating characteristic (HSROC) curve analysis, pretest and post-test probabilities were used for estimating the pathogen detection performance.

Results: A total of 11 studies with 7085 stool samples were eligible for analysis. Multiplex PCRs demonstrated high diagnostic accuracy, with specificity ≧0.98 and area under the ROC curve (AUROC) ≧0.97 for all the pathogens except for Yersinia enterocolitica (AUROC 0.91). The FilmArray panel demonstrated a higher sensitivity than xTAG GPP for most of the pathogens with the exception of Rotavirus A (xTAG GPP and FilmArray were both 0.93).

Conclusions: This is the first meta-analysis that is a head-to-head comparison examining the performance of the novel multiplex PCR-based tests Luminex xTAG GPP and FilmArray GI panel in detecting each pathogen. Point estimates calculated from eligible studies showed that both GI panels are highly accurate and may provide important diagnostic information for early identification of gastroenteritis. In addition, although FilmArray has higher sensitivity and post-test probability than xTAG GPP for most of the pathogens, how this will translate to a clinical setting remains unclear.

Keywords: enteric infections; meta-analysis; real time PCR.

PubMed Disclaimer

Conflict of interest statement

Competing interests: None declared.

Figures

Figure 1
Figure 1
PRISMA flow diagram for selection of articles for meta-analysis. aThese 23 additional studies were identified from the inclusion studies of a systematic review: multiplex tests to identify gastrointestinal bacteria, viruses and parasites in people with suspected infectious gastroenteritis: a systematic review and economic analysis. The systematic review had the same inclusion and exclusion criteria as our study, and included the articles published before 2015. PRISMA, Preferred Reporting Items for Systematic Reviews and Meta-analyses.
Figure 2
Figure 2
QUADAS-2 for included studies. (A) QUADAS-2 risk of bias and concerns regarding applicability graph: review authors' judgements about each domain presented as percentages across included studies. (B) QUADAS-2 risk of bias and concerns regarding applicability summary: review authors' judgements about each domain for each included study. QUADAS-2, quality assessment of diagnostic accuracy studies 2.

References

    1. Farthing M, Salam MA, Lindberg G, et al. . Acute diarrhea in adults and children: a global perspective. J Clin Gastroenterol 2013;47:12–20. 10.1097/MCG.0b013e31826df662 - DOI - PubMed
    1. Chhabra P, Gregoricus N, Weinberg GA, et al. . Comparison of three multiplex gastrointestinal platforms for the detection of gastroenteritis viruses. J Clin Virol 2017;95:66–71. 10.1016/j.jcv.2017.08.012 - DOI - PMC - PubMed
    1. Dryden MS, Gabb RJ, Wright SK. Empirical treatment of severe acute community-acquired gastroenteritis with ciprofloxacin. Clin Infect Dis 1996;22:1019–25. 10.1093/clinids/22.6.1019 - DOI - PubMed
    1. Alejo-Cancho I, Fernández Avilés F, Capón A, et al. . Evaluation of a multiplex panel for the diagnosis of acute infectious diarrhea in immunocompromised hematologic patients. PLoS One 2017;12:e0187458. 10.1371/journal.pone.0187458 - DOI - PMC - PubMed
    1. Duong VT, Phat VV, Tuyen HT, et al. . Evaluation of Luminex xTAG gastrointestinal pathogen panel assay for detection of multiple diarrheal pathogens in fecal samples in Vietnam. J Clin Microbiol 2016;54:1094–100. 10.1128/JCM.03321-15 - DOI - PMC - PubMed

LinkOut - more resources