Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Mar 2;21(1):66.
doi: 10.1186/s12871-021-01285-x.

Heart rate variability-derived features based on deep neural network for distinguishing different anaesthesia states

Affiliations

Heart rate variability-derived features based on deep neural network for distinguishing different anaesthesia states

Jian Zhan et al. BMC Anesthesiol. .

Abstract

Background: Estimating the depth of anaesthesia (DoA) is critical in modern anaesthetic practice. Multiple DoA monitors based on electroencephalograms (EEGs) have been widely used for DoA monitoring; however, these monitors may be inaccurate under certain conditions. In this work, we hypothesize that heart rate variability (HRV)-derived features based on a deep neural network can distinguish different anaesthesia states, providing a secondary tool for DoA assessment.

Methods: A novel method of distinguishing different anaesthesia states was developed based on four HRV-derived features in the time and frequency domain combined with a deep neural network. Four features were extracted from an electrocardiogram, including the HRV high-frequency power, low-frequency power, high-to-low-frequency power ratio, and sample entropy. Next, these features were used as inputs for the deep neural network, which utilized the expert assessment of consciousness level as the reference output. Finally, the deep neural network was compared with the logistic regression, support vector machine, and decision tree models. The datasets of 23 anaesthesia patients were used to assess the proposed method.

Results: The accuracies of the four models, in distinguishing the anaesthesia states, were 86.2% (logistic regression), 87.5% (support vector machine), 87.2% (decision tree), and 90.1% (deep neural network). The accuracy of deep neural network was higher than those of the logistic regression (p < 0.05), support vector machine (p < 0.05), and decision tree (p < 0.05) approaches. Our method outperformed the logistic regression, support vector machine, and decision tree methods.

Conclusions: The incorporation of four HRV-derived features in the time and frequency domain and a deep neural network could accurately distinguish between different anaesthesia states; however, this study is a pilot feasibility study. The proposed method-with other evaluation methods, such as EEG-is expected to assist anaesthesiologists in the accurate evaluation of the DoA.

Keywords: Deep neural network; Depth of anaesthesia; Discrete wavelet transform; Heart rate variability.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Fig. 1
Fig. 1
Flowchart depicting the proposed deep neural network model. DWT: discrete wavelet transform; DNN: deep neural network; EACL: expert assessment of consciousness level
Fig. 2
Fig. 2
Study protocol
Fig. 3
Fig. 3
Correlations between the four features and EACL. a_d Correlations of HF, LF, ratio of HF/LF, and RR interval SampEn with the EACL, respectively. I, II, and III represent anaesthesia induction, anaesthesia maintenance, and anaesthesia recovery, respectively. EACL: expert assessment of consciousness level; HF: high-frequency; LF: low-frequency; HF/LF: high-to-low-frequency ratio
Fig. 4
Fig. 4
ECG data for the proposed method. ac Raw ECG with visible artifacts, filtered ECG with tiny artifacts, and filtered RR intervals. de HF, LF, and ratio of HF/LF. f EACL within the sampling period. HF: high-frequency; LF: low-frequency; HF/LF: high-to-low-frequency ratio; EACL: expert assessment of consciousness level
Fig. 5
Fig. 5
Comparison between anaesthesia states. The Y-axis is logarithmically transformed. (A)–(D) Distributions of (a) HF, (b) LF, (c) the ratio of HF/LF, and (d) the RR interval SampEn values. I, II, and III represent anaesthesia induction, anaesthesia maintenance, and anaesthesia recovery, respectively. Vertical coordinates represent the four feature values. HF: high-frequency; LF: low-frequency; HF/LF: high-to-low-frequency ratio; EACL: expert assessment of consciousness level

References

    1. Lan JY, Abbod MF, Yeh RG, Fan SZ, Shieh JS. Intelligent modeling and control in anesthesia. J Med Biol Eng. 2012;32(5):293–308. doi: 10.5405/jmbe.1014. - DOI
    1. Avidan MS, Jacobsohn E, Glick D, Burnside BA, Zhang L, Villafranca A, et al. Prevention of intraoperative awareness in a high-risk surgical population. N Engl J Med. 2011;365(7):591–600. doi: 10.1056/NEJMoa1100403. - DOI - PubMed
    1. Misal US, Joshi SA, Shaikh MM. Delayed recovery from anesthesia: a postgraduate educational review. Anesth Essays Res. 2016;10(2):164–172. doi: 10.4103/0259-1162.165506. - DOI - PMC - PubMed
    1. Harris M, Chung F. Complications of general anesthesia. Clin Plast Surg. 2013;40(4):503–513. doi: 10.1016/j.cps.2013.07.001. - DOI - PubMed
    1. Hemmings HC, Jr, Akabas MH, Goldstein PA, Trudell JR, Orser BA, Harrison NL. Emerging molecular mechanisms of general anesthetic action. Trends Pharmacol Sci. 2005;26(10):503–510. doi: 10.1016/j.tips.2005.08.006. - DOI - PubMed

Publication types