Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jun;34(3):729-737.
doi: 10.1007/s40620-020-00932-9. Epub 2021 Mar 4.

Comparison of 51Cr-EDTA and 99mTc-DTPA for glomerular filtration rate measurement

Affiliations

Comparison of 51Cr-EDTA and 99mTc-DTPA for glomerular filtration rate measurement

Emmanuelle Vidal-Petiot et al. J Nephrol. 2021 Jun.

Abstract

Purpose: The production of 51Cr-labelled ethylenediaminetetraacetic acid (51Cr-EDTA), a validated and widely used radio-isotopic tracer for glomerular filtration rate (GFR) measurement in Europe, was recently halted by the manufacturer. Technetium-99m-diethylenetriaminepentaacetic acid (99mTc-DTPA) clearance has so far mostly been restricted to assessment of separate renal function by scintigraphy, but scarcely used and validated for GFR measurement. We compared the performances of 51Cr-EDTA and 99mTc-DTPA for GFR and extracellular fluid measurement.

Methods: In a multi-centre prospective study, 51Cr-EDTA and 99mTc-DTPA were simultaneously injected into 88 patients, and their urinary and plasma clearances, as well as their volumes of distribution, were measured during seven 30-min periods after a 90-min equilibrium time.

Results: Mean age was 52.2 ± 14.5 years, 59% were men. Urinary clearances of 51Cr-EDTA and 99mTc-DTPA were 64.1 ± 27.6 and 66.1 ± 28.0 mL/min, respectively, with a mean bias of 2.00 ± 2.25 mL/min, an accuracy within 10% of 95% [95% CI 91-99], and a coefficient of determination (R2) of 0.994. Plasma clearances of 51Cr-EDTA and 99mTc-DTPA were 66.1 ± 25.8 and 68.1 ± 26.6 mL/min, respectively, with a mean bias of 1.96 ± 3.32 mL/min, an accuracy within 10% of 91% [95% CI 85-97] and a R2 of 0.985. Distribution volumes were 17.3 ± 4.6 L for 51Cr-EDTA and 16.6 ± 4.6 L for 99mTc-DTPA (R2 0.930).

Conclusion: The accuracy and precision of 99mTc-DTPA clearance, compared to 51Cr-EDTA clearance, was excellent for both urinary and plasma clearance methods, despite an approximate 2 mL/min overestimation, showing that the tracer is a reliable alternative to 51Cr-EDTA for GFR measurement.

Keywords: 51cr-EDTA; 99mtc-DTPA; Glomerular filtration rate measurement; Plasma clearance; Radio-labelled tracers; Renal clearance.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Levey A, Inker L (2017) Assessment of glomerular filtration rate in health and disease: a state of the art review: state of the art review for clinical pharmacology and therapeutics. Clin Pharmacol Ther 102:405–419. https://doi.org/10.1002/cpt.729 - DOI - PubMed
    1. Soveri I, Berg UB, Björk J et al (2014) Measuring GFR: A Systematic Review. Am J Kidney Dis 64:411–424. https://doi.org/10.1053/j.ajkd.2014.04.010 - DOI - PubMed
    1. Gaspari F, Mosconi L, Viganò G et al (1992) Measurement of GFR with a single intravenous injection of nonradioactive iothalamate. Kidney Int 41:1081–1084 - DOI
    1. Gaspari F, Perico N, Matalone M et al (1998) Precision of plasma clearance of iohexol for estimation of GFR in patients with renal disease. J Am Soc Nephrol 9:310–313 - DOI
    1. Chantler C, Garnett ES, Parsons V, Veall N (1969) Glomerular filtration rate measurement in man by the single injection methods using 51Cr-EDTA. Clin Sci 37:169–180 - PubMed

LinkOut - more resources