Abstract
Ninety-four patients underwent surgery for automatic implantable cardioverter-defibrillator implantation. Ninety patients were discharged from the hospital with the device and were followed up for a mean period of 17 +/- 10 months. Forty-six patients experienced at least one discharge of the device under circumstances consistent with a malignant ventricular arrhythmia. One sudden death occurred. Complications included perioperative death (3 patients), post-operative ventricular tachycardia (12 patients) and atrial fibrillation (8 patients), perioperative myocardial infarction (1 patient) and device discharges for sinus tachycardia and supraventricular arrhythmias (17 patients). Six and 12 month survival rates by life table analysis were 98.7 and 95.4%, respectively. Thus, the automatic implantable cardioverter-defibrillator is a highly effective and relatively low risk treatment modality for patients with refractory life-threatening ventricular arrhythmias.
Similar articles
-
The automatic implantable cardioverter-defibrillator: efficacy, complications, and device failures.Ann Intern Med. 1986 Apr;104(4):481-8. doi: 10.7326/0003-4819-104-4-481. Ann Intern Med. 1986. PMID: 3954276
-
[An automatic implantable cardioverter-defibrillator. The initial clinical experience].Dtsch Med Wochenschr. 1987 Aug 28;112(35):1323-30. doi: 10.1055/s-2008-1068243. Dtsch Med Wochenschr. 1987. PMID: 3622270 German.
-
[Experience with the use of an implantable automatic cardioverter defibrillator].Arch Inst Cardiol Mex. 1990 Sep-Oct;60(5):499-502. Arch Inst Cardiol Mex. 1990. PMID: 2091555 Spanish.
-
Current role of the automatic implantable cardioverter-defibrillator in the treatment of life-threatening ventricular arrhythmias.Am J Med. 1990 Jan;88(1N):25N-34N. Am J Med. 1990. PMID: 2195882 Review.
-
Role of amiodarone in the era of the implantable cardioverter defibrillator.J Cardiovasc Electrophysiol. 2003 Sep;14(9 Suppl):S78-81. doi: 10.1046/j.1540-8167.14.s9.22.x. J Cardiovasc Electrophysiol. 2003. PMID: 12950525 Review.
Cited by
-
Impact of the multicenter automatic defibrillator implantation trial on clinical practice.Ann Noninvasive Electrocardiol. 2006 Jan;11(1):20-7. doi: 10.1111/j.1542-474X.2006.00061.x. Ann Noninvasive Electrocardiol. 2006. PMID: 16472278 Free PMC article.
-
Implantable Cardioverter-Defibrillator for Primary Prevention in Asia.JACC Asia. 2023 Mar 7;3(3):321-334. doi: 10.1016/j.jacasi.2022.11.014. eCollection 2023 Jun. JACC Asia. 2023. PMID: 37323870 Free PMC article. Review.
-
Should all implantable cardioverter defibrillators for ventricular arrhythmias be dual-chamber devices?Curr Cardiol Rep. 2001 Nov;3(6):447-50. doi: 10.1007/s11886-001-0065-2. Curr Cardiol Rep. 2001. PMID: 11602074 Review.
-
Treatment of malignant ventricular arrhythmias with the automatic implantable cardioverter defibrillator.Ann Surg. 1989 May;209(5):635-41; discussion 641. doi: 10.1097/00000658-198905000-00017. Ann Surg. 1989. PMID: 2705827 Free PMC article.
-
Role of orthotopic heart transplantation in the management of patients with recurrent ventricular tachyarrhythmias following myocardial infarction.Heart. 1998 Nov;80(5):473-8. doi: 10.1136/hrt.80.5.473. Heart. 1998. PMID: 9930047 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical