The Validity of MotionSense HRV in Estimating Sedentary Behavior and Physical Activity under Free-Living and Simulated Activity Settings
- PMID: 33670507
- PMCID: PMC7922785
- DOI: 10.3390/s21041411
The Validity of MotionSense HRV in Estimating Sedentary Behavior and Physical Activity under Free-Living and Simulated Activity Settings
Abstract
MotionSense HRV is a wrist-worn accelerometery-based sensor that is paired with a smartphone and is thus capable of measuring the intensity, duration, and frequency of physical activity (PA). However, little information is available on the validity of the MotionSense HRV. Therefore, the purpose of this study was to assess the concurrent validity of the MotionSense HRV in estimating sedentary behavior (SED) and PA. A total of 20 healthy adults (age: 32.5 ± 15.1 years) wore the MotionSense HRV and ActiGraph GT9X accelerometer (GT9X) on their non-dominant wrist for seven consecutive days during free-living conditions. Raw acceleration data from the devices were summarized into average time (min/day) spent in SED and moderate-to-vigorous PA (MVPA). Additionally, using the Cosemed K5 indirect calorimetry system (K5) as a criterion measure, the validity of the MotionSense HRV was examined in simulated free-living conditions. Pearson correlations, mean absolute percent errors (MAPE), Bland-Altman (BA) plots, and equivalence tests were used to examine the validity of the MotionSense HRV against criterion measures. The correlations between the MotionSense HRV and GT9X were high and the MAPE were low for both the SED (r = 0.99, MAPE = 2.4%) and MVPA (r = 0.97, MAPE = 9.1%) estimates under free-living conditions. BA plots illustrated that there was no systematic bias between the MotionSense HRV and criterion measures. The estimates of SED and MVPA from the MotionSense HRV were significantly equivalent to those from the GT9X; the equivalence zones were set at 16.5% for SED and 29% for MVPA. The estimates of SED and PA from the MotionSense HRV were less comparable when compared with those from the K5. The MotionSense HRV yielded comparable estimates for SED and PA when compared with the GT9X accelerometer under free-living conditions. We confirmed the promising application of the MotionSense HRV for monitoring PA patterns for practical and research purposes.
Keywords: MotionSense HRV; accelerometer; mobile health; physical activity; sedentary behavior; validity.
Conflict of interest statement
The authors declare no conflict of interest.
Figures




Similar articles
-
Concurrent validity of the Fitbit for assessing sedentary behavior and moderate-to-vigorous physical activity.BMC Med Res Methodol. 2019 Feb 7;19(1):29. doi: 10.1186/s12874-019-0668-1. BMC Med Res Methodol. 2019. PMID: 30732582 Free PMC article.
-
Validation of the Apple Watch for Estimating Moderate-to-Vigorous Physical Activity and Activity Energy Expenditure in School-Aged Children.Sensors (Basel). 2021 Sep 25;21(19):6413. doi: 10.3390/s21196413. Sensors (Basel). 2021. PMID: 34640733 Free PMC article.
-
Inter-Device Agreement between Fitbit Flex 1 and 2 for Assessing Sedentary Behavior and Physical Activity.Int J Environ Res Public Health. 2021 Mar 8;18(5):2716. doi: 10.3390/ijerph18052716. Int J Environ Res Public Health. 2021. PMID: 33800254 Free PMC article.
-
Assessment of Physical Activity in Adults Using Wrist Accelerometers.Epidemiol Rev. 2022 Jan 14;43(1):65-93. doi: 10.1093/epirev/mxab004. Epidemiol Rev. 2022. PMID: 34215874 Free PMC article. Review.
-
There Is a Clinical Need to Consider the Physical Activity: Sedentary Pattern in Children with Obesity - Position Paper of the European Childhood Obesity Group.Ann Nutr Metab. 2022;78(4):236-241. doi: 10.1159/000524570. Epub 2022 May 2. Ann Nutr Metab. 2022. PMID: 35500549 Review.
Cited by
-
Current Knowledge about ActiGraph GT9X Link Activity Monitor Accuracy and Validity in Measuring Steps and Energy Expenditure: A Systematic Review.Sensors (Basel). 2024 Jan 26;24(3):825. doi: 10.3390/s24030825. Sensors (Basel). 2024. PMID: 38339541 Free PMC article.
-
Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review.JMIR Mhealth Uhealth. 2022 Jun 9;10(6):e36377. doi: 10.2196/36377. JMIR Mhealth Uhealth. 2022. PMID: 35679106 Free PMC article.
-
Assessing the Impact of Context Inference Error and Partial Observability on RL Methods for Just-In-Time Adaptive Interventions.Proc Mach Learn Res. 2023 Aug;216:1047-1057. Proc Mach Learn Res. 2023. PMID: 37724310 Free PMC article.
-
An Examination of the Feasibility of Detecting Cocaine Use Using Smartwatches.Front Psychiatry. 2021 Jun 24;12:674691. doi: 10.3389/fpsyt.2021.674691. eCollection 2021. Front Psychiatry. 2021. PMID: 34248712 Free PMC article.
-
Disagreements in physical activity monitor validation study guidelines create challenges in conducting validity studies.Front Digit Health. 2023 Jan 10;4:1063324. doi: 10.3389/fdgth.2022.1063324. eCollection 2022. Front Digit Health. 2023. PMID: 36703940 Free PMC article. No abstract available.
References
-
- World Health Organization . mHealth: New Horizons for Health through Mobile Technologies. World Health Organization; Geneva, Switzerland: 2011.
-
- Kumar S., Nilsen W., Pavel M., Srivastava M. Mobile health: Revolutionizing healthcare through transdisciplinary research. Computer. 2013;46:28–35. doi: 10.1109/MC.2012.392. - DOI
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials