Fracture Load of Metal, Zirconia and Polyetheretherketone Posterior CAD-CAM Milled Fixed Partial Denture Frameworks
- PMID: 33670544
- PMCID: PMC7922591
- DOI: 10.3390/ma14040959
Fracture Load of Metal, Zirconia and Polyetheretherketone Posterior CAD-CAM Milled Fixed Partial Denture Frameworks
Abstract
The aim of this study was to investigate the load to fracture and fracture pattern of prosthetic frameworks for tooth-supported fixed partial dentures (FPDs) fabricated with different subtractive computer-aided design and computer-aided manufacturing (CAD-CAM) materials.
Materials and methods: Thirty standardized specimens with two abutments were fabricated to receive three-unit posterior FDP frameworks with an intermediate pontic. Specimens were randomly divided into three groups (n = 10 each) according to the material: group 1 (MM)-milled metal; group 2 (L)-zirconia; and group 3 (P)-Polyetheretherketone (PEEK). The specimens were thermo-cycled and subjected to a three-point bending test until fracture using a universal testing machine (cross-head speed: 1 mm/min). Axial compressive loads were applied at the central fossa of the pontics. Data analysis was made using one-way analysis of variance, Tamhane post hoc test, and Weibull statistics (α = 0.05).
Results: Significant differences were observed among the groups for the fracture load (p < 0.0001). MM frameworks showed the highest fracture load values. The PEEK group registered higher fracture load values than zirconia samples. The Weibull statistics corroborated these results. The fracture pattern was different among the groups.
Conclusions: Milled metal provided the highest fracture load values, followed by PEEK, and zirconia. However, all tested groups demonstrated clinically acceptable fracture load values higher than 1000 N. PEEK might be considered a promising alternative for posterior FPDs.
Keywords: CAD-CAM; PEEK; fixed partial dentures; fracture load; zirconia.
Conflict of interest statement
The authors deny any conflict of interest.
Figures





Similar articles
-
Effect of Thermomechanical and Static Loading on the Load to Fracture of Metal-Ceramic, Monolithic, and Veneered Zirconia Posterior Fixed Partial Dentures.J Prosthodont. 2019 Feb;28(2):171-178. doi: 10.1111/jopr.13008. Epub 2019 Jan 1. J Prosthodont. 2019. PMID: 30548895
-
Fracture load of metal-ceramic, monolithic, and bi-layered zirconia-based posterior fixed dental prostheses after thermo-mechanical cycling.J Dent. 2018 Jun;73:97-104. doi: 10.1016/j.jdent.2018.04.012. Epub 2018 Apr 17. J Dent. 2018. PMID: 29678585
-
Influence of Digital Technologies and Framework Design on the Load to Fracture of Co-Cr Posterior Fixed Partial Denture Frameworks.J Prosthodont. 2022 Aug;31(7):606-613. doi: 10.1111/jopr.13458. Epub 2021 Dec 23. J Prosthodont. 2022. PMID: 34860426
-
Fracture Load Before and After Veneering Zirconia Posterior Fixed Dental Prostheses.J Prosthodont. 2016 Oct;25(7):550-556. doi: 10.1111/jopr.12357. Epub 2015 Sep 18. J Prosthodont. 2016. PMID: 26380955
-
Load-Bearing Capacity of Posterior CAD/CAM Implant-Supported Fixed Partial Dentures Fabricated with Different Esthetic Materials.Int J Prosthodont. 2019 Mar/Apr;32(2):201-204. doi: 10.11607/ijp.6128. Int J Prosthodont. 2019. PMID: 30856647
Cited by
-
Effect of veneering material type and thickness ratio on flexural strength of bi-layered PEEK restorations before and after thermal cycling.Clin Oral Investig. 2023 Jun;27(6):2629-2639. doi: 10.1007/s00784-022-04829-8. Epub 2023 Jan 5. Clin Oral Investig. 2023. PMID: 36602589 Free PMC article.
-
PEEK in Fixed Dental Prostheses: Application and Adhesion Improvement.Polymers (Basel). 2022 Jun 8;14(12):2323. doi: 10.3390/polym14122323. Polymers (Basel). 2022. PMID: 35745900 Free PMC article. Review.
-
Effect of cement spacer on fit accuracy and fracture strength of 3-unit and 4-unit zirconia frameworks.BMC Oral Health. 2024 May 21;24(1):586. doi: 10.1186/s12903-024-04341-3. BMC Oral Health. 2024. PMID: 38773502 Free PMC article.
-
Comparison of fracture resistance of implant-supported fixed prothesis substructure materials with different cross-sectional geometry.BMC Oral Health. 2025 Apr 26;25(1):645. doi: 10.1186/s12903-025-06033-y. BMC Oral Health. 2025. PMID: 40287636 Free PMC article.
-
Shear Bond Strength of Two Repair Systems to Zirconia Ceramic by Different Surface Treatments.J Lasers Med Sci. 2022 Jul 19;13:e31. doi: 10.34172/jlms.2022.31. eCollection 2022. J Lasers Med Sci. 2022. PMID: 36743152 Free PMC article.
References
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous