Fully automated peptide mapping multi-attribute method by liquid chromatography-mass spectrometry with robotic liquid handling system
- PMID: 33676166
- DOI: 10.1016/j.jpba.2021.113988
Fully automated peptide mapping multi-attribute method by liquid chromatography-mass spectrometry with robotic liquid handling system
Abstract
The multi-attribute method (MAM) based on liquid chromatography (LC)-tandem mass spectrometry is emerging as a powerful tool to directly monitor multiple product quality attributes simultaneously. To better implement MAM, either for product characterization or for quality control (QC), there is a need for a robust, universal, and high-throughput workflow that can be broadly adopted in different laboratories with minimal barriers to implementation. Manual preparation of samples for MAM, however, is labor intensive and produces nontrivial variations across analysts and laboratories. We describe the development of a fully automated peptide mapping procedure with a high-throughput robotic liquid handling system to improve sample handling capacity and outcome reproducibility while saving analyst hands-on time. Our procedure features the automation of a "microdialysis" step, an efficient desalting approach prior to proteolytic digestion that optimizes digestion completeness and consistency each time. The workflow is completely hands-free and requires the analyst only to pre-normalize the sample concentrations and to load buffers and reagents at their designated positions on the robotic deck. The robotic liquid handler performs all the subsequent preparation steps and stores the digested samples on a chiller unit to await retrieval for further analysis. We also demonstrate that the manual and automated procedures are comparable with regard to protein sequence coverage, digestion completeness and consistency, and quantification of posttranslational modifications. Notably, in contrast to a previously reported automated sample preparation protocol that relied on customized accessories, all components in our automation procedure are commercial products that are readily available. In addition, we also present the high-throughput data analysis workflow by using Protein Metrics. The automation procedure can be applied cross-functionally in the biopharmaceutical industry and, given its practicality and reproducibility, can pave the way for MAM implementation in QC laboratories.
Keywords: Automation; LC–MS; Microdialysis; Multi-attribute method; Peptide mapping.
Copyright © 2021 The Authors. Published by Elsevier B.V. All rights reserved.
Conflict of interest statement
Declaration of Competing Interest The authors report no declarations of interest.
Similar articles
-
Mass spectrometry-based multi-attribute method in protein therapeutics product quality monitoring and quality control.MAbs. 2023 Jan-Dec;15(1):2197668. doi: 10.1080/19420862.2023.2197668. MAbs. 2023. PMID: 37057828 Free PMC article. Review.
-
Enhancing the multi-attribute method through an automated and high-throughput sample preparation.MAbs. 2021 Jan-Dec;13(1):1978131. doi: 10.1080/19420862.2021.1978131. MAbs. 2021. PMID: 34586946 Free PMC article.
-
Inter-laboratory study of an optimised peptide mapping workflow using automated trypsin digestion for monitoring monoclonal antibody product quality attributes.Anal Bioanal Chem. 2020 Oct;412(25):6833-6848. doi: 10.1007/s00216-020-02809-z. Epub 2020 Jul 25. Anal Bioanal Chem. 2020. PMID: 32710279 Free PMC article.
-
Multi-Attribute Method (MAM) Analytical Workflow for Biotherapeutic Protein Characterization from Process Development to QC.Curr Protoc. 2023 Nov;3(11):e927. doi: 10.1002/cpz1.927. Curr Protoc. 2023. PMID: 37929772
-
Multi-Attribute Method (MAM): An Emerging Analytical Workflow for Biopharmaceutical Characterization, Batch Release and cGMP Purity Testing at the Peptide and Intact Protein Level.Crit Rev Anal Chem. 2024;54(8):3234-3251. doi: 10.1080/10408347.2023.2238058. Epub 2023 Jul 25. Crit Rev Anal Chem. 2024. PMID: 37490277 Review.
Cited by
-
Optimized Multi-Attribute Method Workflow Addressing Missed Cleavages and Chromatographic Tailing/Carry-Over of Hydrophobic Peptides.Anal Chem. 2022 Dec 13;94(49):17195-17204. doi: 10.1021/acs.analchem.2c03820. Epub 2022 Nov 8. Anal Chem. 2022. PMID: 36346901 Free PMC article.
-
Targeted CQA analytical control strategy for commercial antibody products: Replacing ion-exchange chromatography methods for charge heterogeneity with multi-attribute monitoring.MAbs. 2024 Jan-Dec;16(1):2341641. doi: 10.1080/19420862.2024.2341641. Epub 2024 Apr 23. MAbs. 2024. PMID: 38652517 Free PMC article.
-
Mass spectrometry-based multi-attribute method in protein therapeutics product quality monitoring and quality control.MAbs. 2023 Jan-Dec;15(1):2197668. doi: 10.1080/19420862.2023.2197668. MAbs. 2023. PMID: 37057828 Free PMC article. Review.
-
Enhancing the multi-attribute method through an automated and high-throughput sample preparation.MAbs. 2021 Jan-Dec;13(1):1978131. doi: 10.1080/19420862.2021.1978131. MAbs. 2021. PMID: 34586946 Free PMC article.
-
Comprehensive multi-attribute method workflow for biotherapeutic characterization and current good manufacturing practices testing.Nat Protoc. 2023 Apr;18(4):1056-1089. doi: 10.1038/s41596-022-00785-5. Epub 2022 Dec 16. Nat Protoc. 2023. PMID: 36526726 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources