[Noninvasive determination of oxygen saturation using pulse oximetry in pediatric cardiology]
- PMID: 3367912
[Noninvasive determination of oxygen saturation using pulse oximetry in pediatric cardiology]
Abstract
Pulse oximetry is a relatively new noninvasive method to measure arterial oxygen saturation (SO2). We evaluated the reliability of a pulse oximeter (N-100, Nellcor/Drger, Lübeck) in single and continuous measurements of SO2. During cardiac catheterisation we compared pulse oximeter (puls.SO2) measurements to those in simultaneously taken arterial samples (art.SO2), and obtained 203 pair measurements in 85 patients, mostly newborns and infants; in 20 of them before and during the breathing of oxygen through a mask. We also have 67 pair measurements of capillary blood samples (kap.SO2) and puls.SO2. Continuous measurements with the pulse oximeter were carried out in 17 patients for up to 116 h. Our main results are: 1. In the puls.SO2 range of 66% to 100% the measurements with the pulse oximeter were accurate (r = 0.97, Syx = 2.1). Below 66% the puls.SO2 values were on average much higher than the art.SO2 values, with an increased variance. Intraindividual oxygenation changes before and during the breathing of oxygen were accurately measured. 2. Pulse oximetry is much more informative than kap.SO2 measurements, because its information about the SO2 before blood sampling (= resting value) and following SO2 changes during the painful procedure (= stress values). 3. Continuous measurements with the pulse oximeter are very simple and very reliable and are not associated with skin injury. Because the pulse oximeters responses rapid to oxygenation changes and does not need calibration it is very valuable in the assessment of therapeutic procedures in patients with cyanotic heart disease. We conclude that the pulse oximeter is a very important new diagnostic tool in pediatric cardiology.
Similar articles
-
Pulse oximetry: an alternative method for the assessment of oxygenation in newborn infants.Pediatrics. 1987 Apr;79(4):524-8. Pediatrics. 1987. PMID: 2434911
-
[Reliability and limitations of pulse oximetry in corrective cyanotic heart surgery].Anaesthesist. 1989 Jun;38(6):302-8. Anaesthesist. 1989. PMID: 2764270 German.
-
Pulse oximetry in very low birth weight infants with acute and chronic lung disease.Pediatrics. 1987 Apr;79(4):612-7. Pediatrics. 1987. PMID: 2434913
-
[Arterial puncture or pulse oximetry?].Ugeskr Laeger. 1999 Feb 22;161(8):1100-2. Ugeskr Laeger. 1999. PMID: 10074849 Review. Danish.
-
Pulse oximetry: a review of the theory, accuracy, and clinical applications.Obstet Gynecol. 1989 Sep;74(3 Pt 2):541-6. Obstet Gynecol. 1989. PMID: 2668828 Review.
Cited by
-
Success and time implications of SpO2 measurement through pulse oximetry among hospitalised children in rural Bangladesh: Variability by various device-, provider- and patient-related factors.J Glob Health. 2022 Apr 23;12:04036. doi: 10.7189/jogh.12.04036. eCollection 2022. J Glob Health. 2022. PMID: 35493782 Free PMC article.
-
Evaluation of visible diffuse reflectance spectroscopy in liver tissue: validation of tissue saturations using extracorporeal circulation.J Biomed Opt. 2021 May;26(5):055002. doi: 10.1117/1.JBO.26.5.055002. J Biomed Opt. 2021. PMID: 34021537 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Medical