Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port
- PMID: 33686152
- PMCID: PMC7940397
- DOI: 10.1038/s41598-021-84885-4
Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port
Abstract
Central venous port (CVP) is a widely used totally implantable venous access device. Recognition of risks associated with CVP-related complications is clinically important for safe, reliable, and long-term intravenous access. We therefore investigated factors associated with CVP infection and evulsion, including the device type. A total of 308 consecutive patients with initial CVP implantation between January 2011 and December 2017 were retrospectively reviewed, and the association of clinical features with CVP-related complications were analyzed. Intraoperative and postoperative complications occurred in 11 (3.6%) and 39 (12.7%) patients, respectively. The overall rate of CVP availability at six months was 91.4%. Malignancy and 2-Methacryloyloxyethyl phosphorylcholine (MPC) polymer-coated catheter use were negatively associated with the incidence of CVP infections. Accordingly, malignancy and MPC polymer-coated catheter use were independent predictors for lower CVP evulsion rate (odds ratio, 0.23 and 0.18, respectively). Furthermore, both factors were significantly associated with longer CVP availability (hazard ratio, 0.24 and 0.27, respectively). This retrospective study identified factors associated with CVP-related complications and long-term CVP availability. Notably, MPC polymer-coated catheter use was significantly associated with a lower rate of CVP infection and longer CVP availability, suggesting the preventive effect of MPC coating on CVP infection.
Conflict of interest statement
The authors declare no competing interests.
Figures

Similar articles
-
Clinical outcomes of totally implantable venous access port placement via the axillary vein in patients with head and neck malignancy.J Vasc Access. 2019 Mar;20(2):134-139. doi: 10.1177/1129729818781270. Epub 2018 Jun 20. J Vasc Access. 2019. PMID: 29923460
-
Late complications associated with totally implantable venous access port implantation via the internal jugular vein.Support Care Cancer. 2020 Jun;28(6):2761-2768. doi: 10.1007/s00520-019-05122-3. Epub 2019 Nov 14. Support Care Cancer. 2020. PMID: 31724073
-
Increased rates of local complication of central venous catheters in the targeted anticancer therapy era: a 2-year retrospective analysis.Support Care Cancer. 2015 May;23(5):1295-302. doi: 10.1007/s00520-014-2466-y. Epub 2014 Oct 19. Support Care Cancer. 2015. PMID: 25326782
-
Infection of totally implantable venous access devices: A review of the literature.J Vasc Access. 2018 May;19(3):230-242. doi: 10.1177/1129729818758999. Epub 2018 Mar 7. J Vasc Access. 2018. PMID: 29512430 Review.
-
Central venous catheter-associated infections.Best Pract Res Clin Anaesthesiol. 2008 Sep;22(3):407-21. doi: 10.1016/j.bpa.2008.05.007. Best Pract Res Clin Anaesthesiol. 2008. PMID: 18831295 Review.
Cited by
-
[Clinical Practice and Quality Control Guidelines for Totally Implantable Venous Access Ports in Cancer Patients (2024)].Sichuan Da Xue Xue Bao Yi Xue Ban. 2025 Mar 20;56(2):400-410. doi: 10.12182/20250360602. Sichuan Da Xue Xue Bao Yi Xue Ban. 2025. PMID: 40599273 Free PMC article. Chinese.
-
Biomimetic materials based on zwitterionic polymers toward human-friendly medical devices.Sci Technol Adv Mater. 2022 Sep 13;23(1):498-524. doi: 10.1080/14686996.2022.2119883. eCollection 2022. Sci Technol Adv Mater. 2022. PMID: 36117516 Free PMC article. Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources