Incidence and morbidity of extubation failure in surgical intensive care patients
- PMID: 3371019
- DOI: 10.1097/00003246-198806000-00001
Incidence and morbidity of extubation failure in surgical intensive care patients
Abstract
The rate of extubation failure (reintubation rate) was determined for 700 consecutive extubations in surgical patients admitted to one of two ICUs. Patients were weaned in a standardized fashion and extubated using a standardized gas exchange and mechanics criteria. Of 400 extubations in the general surgical ICU, there were 22 reintubations in 20 patients. Average age was 65 yr, and the major reason for reintubation was need for positive-pressure ventilation. Morbidity (pulmonary edema and/or pneumonia) was 36%, and the inhospital mortality was 40% in this group. The major cause of death was progressive cardiopulmonary failure. There were 10 failures in eight patients, of 300 extubations in the Burn/Trauma unit, where the mean age was 44 yr. Five failures occurred in patients with smoke inhalation and burns, a 13% incidence in this population. The reason for reintubation was airway maintenance and pulmonary toilet. Four failures occurred in head injury patients, a 5% incidence with the major reason for reintubation being airway protection. Morbidity was 60% (new pulmonary infiltrates), while mortality rate was only 10% in this group. Only one failure was noted in a nonhead-injured trauma patient. In no group studied were any predictors of extubation failure detected. We conclude that the incidence, reasons for, and outcome of reintubations in surgical ICU patients varies dramatically depending on the underlying disease process. Overall failure rate was 4%.
Similar articles
-
The incidence and outcome of extubation failure in burn intensive care patients.J Burn Care Res. 2009 May-Jun;30(3):386-92. doi: 10.1097/BCR.0b013e3181a2894c. J Burn Care Res. 2009. PMID: 19349900
-
Risk factors associated with early reintubation in trauma patients: a prospective observational study.J Trauma. 2011 Jul;71(1):37-41; discussion 41-2. doi: 10.1097/TA.0b013e31821e0c6e. J Trauma. 2011. PMID: 21818012
-
Breathing measurement reduces false-negative classification of tachypneic preextubation trial failures.Crit Care Med. 1996 Jun;24(6):976-80. doi: 10.1097/00003246-199606000-00017. Crit Care Med. 1996. PMID: 8681601
-
A Multifaceted Extubation Protocol to Reduce Reintubation Rates in the Surgical ICU.Jt Comm J Qual Patient Saf. 2022 Feb;48(2):81-91. doi: 10.1016/j.jcjq.2021.09.008. Epub 2021 Sep 24. Jt Comm J Qual Patient Saf. 2022. PMID: 34756824 Review.
-
Non-invasive ventilation for weaning, avoiding reintubation after extubation and in the postoperative period: a meta-analysis.Br J Anaesth. 2012 Sep;109(3):305-14. doi: 10.1093/bja/aes270. Br J Anaesth. 2012. PMID: 22879654 Review.
Cited by
-
Predictors of extubation failure and prolonged mechanical ventilation among patients with intracerebral hemorrhage after surgery.Respir Res. 2024 Jan 4;25(1):19. doi: 10.1186/s12931-023-02638-5. Respir Res. 2024. PMID: 38178114 Free PMC article.
-
Assisted ventilation. 4. Weaning from mechanical ventilation.Thorax. 1991 Jan;46(1):56-62. doi: 10.1136/thx.46.1.56. Thorax. 1991. PMID: 1871697 Free PMC article. Review. No abstract available.
-
The use of an endotracheal ventilation catheter in the management of difficult extubations.Can J Anaesth. 1996 Jan;43(1):90-3. doi: 10.1007/BF03015965. Can J Anaesth. 1996. PMID: 8665644
-
Evaluation of a systematic approach to weaning of tracheotomized neurological patients: an early interrupted randomized controlled trial.Ann Intensive Care. 2015 Dec;5(1):54. doi: 10.1186/s13613-015-0098-0. Epub 2015 Dec 23. Ann Intensive Care. 2015. PMID: 26698596 Free PMC article.
-
[EXTUBATION FAILURE IN BURNS: INCIDENCE, RISK FACTORS AND PROGNOSIS].Ann Burns Fire Disasters. 2024 Jun 30;37(2):112-117. eCollection 2024 Jun. Ann Burns Fire Disasters. 2024. PMID: 38974788 Free PMC article. French.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical