Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jan-Mar;17(1):148-151.
doi: 10.4103/jcrt.JCRT_95_18.

Implementation of a visual feedback system for motion management during radiation therapy

Affiliations
Free article

Implementation of a visual feedback system for motion management during radiation therapy

Jamema Swamidas et al. J Cancer Res Ther. 2021 Jan-Mar.
Free article

Abstract

Purpose: To describe the details of an in-house video goggles feedback system assembled from several commercially available components. The objective of this paper is to share our experience with this system, provide details on the equipment needed, system assembly, patient set up and user settings on some components.

Materials and methods: The system consisted of goggles (FPView3DHD, ITV, USA), RJ45(Registered Jack) to Digital Visual Interface (DVI) converter (Tripplite), DVI to HDMI converters, Local Area Network(LAN) cable, HDMI and power extender cables. The video coaching system was implemented both in CT simulator (GE Discovery)) and in treatment delivery machine True Beam v2.1 Varian Medical Systems (VMS, Palo Alto), which was integrated with respiratory motion management (RPM V 1.7.5) system.

Results: The video feedback system is in clinical use since Aug 2017, so far, we have treated 13 patients, with approximately 150 fractions. The performance of the device was found to be satisfactory. All the patients were coached for DIBH and the usage of the goggles, which includes wearing the goggles, display details of the monitor, and the threshold levels of the breathing wave cycle. The patients understand the instructions very well and hence regulate the breathing cycle, which improves the treatment accuracy and efficiency.

Conclusion: Video feedback system for motion management, for patients undergoing radiotherapy was implemented successfully both in CT simulator and in linear accelerator.

Keywords: Deep inspiration breadth hold (DIBH); motion management; visual feedback system.