The effect of post-sintering heat treatments on the fatigue properties of porous coated Ti-6Al-4V alloy
- PMID: 3372550
- DOI: 10.1002/jbm.820220404
The effect of post-sintering heat treatments on the fatigue properties of porous coated Ti-6Al-4V alloy
Abstract
Porous coated Ti-6Al-4V alloy implant systems provide a biocompatible interface between implant and bone, resulting in firm fixation and potential long-term retention via bony ingrowth. In order to achieve an acceptable porous coating structure, the sintering protocol for Ti-6Al-4V alloy systems often requires that the material be heat treated above the beta transus. This transforms the as-received equiaxed microstructure, recommended for surgical implants, to a lamellar alpha-beta distribution, which has been shown to have the worst fatigue properties of the most common structures attainable in Ti-6Al-4V alloy. However, post-sintering heat treatments may be used to improve these properties by producing microstructures more resistant to crack initiation and propagation. This study investigated the influence of microstructural variations on the fatigue properties of porous coated Ti-6Al-4V alloy material. Nonporous coated and porous coated Ti-6Al-4V alloy fatigue specimens were subjected to a standard sintering heat treatment to produce a lamellar microstructure. In addition, two post-sintering heat treatments were used to produce coarse and fine acicular microstructures. Rotating beam (reversed bending) fatigue testing was performed and the endurance limits determined for the noncoated and porous coated microstructures. The values determined were 668 MPa (noncoated as-received equiaxed), 394 MPa (noncoated lamellar), 488 MPa (non-coated coarse acicular), 494 MPa (noncoated fine acicular), 140 MPa (porous coated lamellar), 161 MPa (porous coated coarse acicular), and 162 MPa (porous coated fine acicular). The noncoated coarse and fine acicular specimens displayed an approximate 25% increase over the noncoated lamellar specimens. The porous coated coarse and fine acicular specimens showed an approximate 15% improvement over the porous coated lamellar specimens.
Similar articles
-
Fatigue properties of carbon- and porous-coated Ti-6Al-4V alloy.J Biomed Mater Res. 1984 May-Jun;18(5):497-512. doi: 10.1002/jbm.820180504. J Biomed Mater Res. 1984. PMID: 6736080
-
A parametric study of the factors affecting the fatigue strength of porous coated Ti-6A1-4V implant alloy.J Biomed Mater Res. 1990 Nov;24(11):1483-501. doi: 10.1002/jbm.820241106. J Biomed Mater Res. 1990. PMID: 2279982
-
The fatigue strength of porous-coated Ti-6%Al-4%V implant alloy.J Biomed Mater Res. 1984 Nov-Dec;18(9):1043-58. doi: 10.1002/jbm.820180908. J Biomed Mater Res. 1984. PMID: 6544792
-
Improvement of the fatigue life of titanium alloys for biomedical devices through microstructural control.Expert Rev Med Devices. 2010 Jul;7(4):481-8. doi: 10.1586/erd.10.16. Expert Rev Med Devices. 2010. PMID: 20583885 Review.
-
Bio-mechanical analysis of porous Ti-6Al-4V scaffold: a comprehensive review on unit cell structures in orthopaedic application.Biomed Phys Eng Express. 2024 Oct 14;10(6). doi: 10.1088/2057-1976/ad8202. Biomed Phys Eng Express. 2024. PMID: 39353464 Review.
Cited by
-
A comparison of the corrosion behaviour and surface characteristics of vacuum-brazed and heat-treated Ti6Al4V alloy.J Mater Sci Mater Med. 1998 Aug;9(8):429-37. doi: 10.1023/a:1008863232494. J Mater Sci Mater Med. 1998. PMID: 15348855
-
Surface characteristics of Ti6Al4V alloy: effect of materials, passivation and autoclaving.J Mater Sci Mater Med. 1998 Aug;9(8):439-48. doi: 10.1023/a:1008815316564. J Mater Sci Mater Med. 1998. PMID: 15348856
-
Effect of passivation and surface modification on the dissolution behavior and nano-surface characteristics of Ti-6Al-4V in Hank/EDTA solution.J Mater Sci Mater Med. 2006 Jan;17(1):15-27. doi: 10.1007/s10856-006-6325-3. J Mater Sci Mater Med. 2006. PMID: 16389468
-
Mechanical compatibility of sol-gel annealing with titanium for orthopaedic prostheses.J Mater Sci Mater Med. 2016 Jan;27(1):21. doi: 10.1007/s10856-015-5611-3. Epub 2015 Dec 21. J Mater Sci Mater Med. 2016. PMID: 26691162 Free PMC article.
-
Additive manufacturing technique-designed metallic porous implants for clinical application in orthopedics.RSC Adv. 2018 Jul 16;8(44):25210-25227. doi: 10.1039/c8ra04815k. eCollection 2018 Jul 9. RSC Adv. 2018. PMID: 35542139 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources