A Point-of-Care Algorithm to Guide Proper Device Selection for Ambulatory Electrocardiography
- PMID: 33731601
- DOI: 10.1097/HPC.0000000000000259
A Point-of-Care Algorithm to Guide Proper Device Selection for Ambulatory Electrocardiography
Abstract
In the outpatient setting, ambulatory electrocardiography is the most frequently used diagnostic modality for the evaluation of patients in whom cardiac arrhythmias or conduction abnormalities are suspected. Proper selection of the device type and monitoring duration is critical for optimizing diagnostic yield and cost-effective resource utilization. However, despite guidance from major professional societies, the lack of systematic guidance for proper test selection in many institutions results in the need for repeat testing, which leads to not only increased resource utilization and cost of care, but also suboptimal patient care. To address this unmet need at our own institution, we formed a multidisciplinary panel to develop a concise, yet comprehensive algorithm, incorporating the most common indications for ambulatory electrocardiography, to efficiently guide clinicians to the most appropriate test option for a given clinical scenario, with the goal of maximizing diagnostic yield and optimizing resource utilization. The algorithm was designed as a single-page, color-coded flowchart to be utilized both as a rapid reference guide in printed form, and a decision support tool embedded within the electronic medical records system at the point of order entry. We believe that systematic adoption of this algorithm will optimize diagnostic efficiency, resource utilization, and importantly, patient care and satisfaction.
Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.
References
-
- Joshi AK, Kowey PR, Prystowsky EN, et al. First experience with a Mobile Cardiac Outpatient Telemetry (MCOT) system for the diagnosis and management of cardiac arrhythmia. Am J Cardiol. 2005;95:878–881.
-
- Olson JA, Fouts AM, Padanilam BJ, et al. Utility of mobile cardiac outpatient telemetry for the diagnosis of palpitations, presyncope, syncope, and the assessment of therapy efficacy. J Cardiovasc Electrophysiol. 2007;18:473–477.
-
- Pürerfellner H, Sanders P, Pokushalov E, et al.; Reveal LINQ Usability Study Investigators. Miniaturized reveal LINQ insertable cardiac monitoring system: first-in-human experience. Heart Rhythm. 2015;12:1113–1119.
-
- Rosenberg MA, Samuel M, Thosani A, et al. Use of a noninvasive continuous monitoring device in the management of atrial fibrillation: a pilot study. Pacing Clin Electrophysiol. 2013;36:328–333.
-
- Crawford MH, Bernstein SJ, Deedwania PC, et al. ACC/AHA guidelines for ambulatory electrocardiography: executive summary and recommendations. A report of the American College of Cardiology/American Heart Association task force on practice guidelines (committee to revise the guidelines for ambulatory electrocardiography). Circulation. 1999;100:886–893.
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources