Mathematical models for shear-induced blood damage based on vortex platform
- PMID: 33740880
- DOI: 10.1177/03913988211003587
Mathematical models for shear-induced blood damage based on vortex platform
Abstract
Non-physiological shear stress in Ventricular Assist Device (VAD) is considered to be an important trigger of blood damage, which has become the biggest shackle for clinical application. The researches on blood damage in literature were limited to qualitative but did not make much quantitative analysis. The purpose of this study was to investigate the quantitative influence of two flow-dependent parameters: shear stress (rotational speed) and exposure time on the shear-induced damage of red blood cells and von Willebrand Factor (vWF). A vortex blood-shearing platform was constructed to conduct in vitro experiments. Free hemoglobin assay and vWF molecular weight analysis were then performed on the sheared blood samples. MATLAB was used for regression fitting of original experimental data. The quantitative correlations between the hemolysis index, the degradation of high molecular weight vWF and the two flow-dependent parameters were found both following the power law model. The mathematic models indicated that the sensitivity of blood damage on red blood cells and vWF to exposure time was both greater than that of shear stress. Besides, the damage of vWF was more serious than that of red blood cells at the same flow condition. The models could be used to predict blood damage in blood-contacting medical devices, especially for the slow even stagnant blood flow regions in VAD, thus may provide useful guidance for VAD development and improvement. It also indicated that the vortex platform can be used to study the law of blood damage for the simple structure and easy operation.
Keywords: Hemolysis; exposure time; power law model; shear stress; vWF.
Similar articles
-
In vitro study of red blood cell and VWF damage in mechanical circulatory support devices based on blood-shearing platform.Proc Inst Mech Eng H. 2022 Jun;236(6):860-866. doi: 10.1177/09544119221088420. Epub 2022 Apr 3. Proc Inst Mech Eng H. 2022. PMID: 35369808
-
Shear Stress-Induced Total Blood Trauma in Multiple Species.Artif Organs. 2017 Oct;41(10):934-947. doi: 10.1111/aor.12932. Epub 2017 Jul 26. Artif Organs. 2017. PMID: 28744884
-
The influence of surface roughness on the damage of von Willebrand Factor under shear flow condition.Int J Artif Organs. 2022 Apr;45(4):412-420. doi: 10.1177/03913988211056961. Epub 2021 Nov 4. Int J Artif Organs. 2022. PMID: 34736346
-
von Willebrand factor disruption and continuous-flow circulatory devices.J Heart Lung Transplant. 2017 Nov;36(11):1155-1163. doi: 10.1016/j.healun.2017.06.004. Epub 2017 Jun 12. J Heart Lung Transplant. 2017. PMID: 28756118 Review.
-
Role of fluid shear stress in regulating VWF structure, function and related blood disorders.Biorheology. 2015;52(5-6):319-35. doi: 10.3233/BIR-15061. Biorheology. 2015. PMID: 26600266 Free PMC article. Review.
Cited by
-
A comprehensive comparison of the in vitro hemocompatibility of extracorporeal centrifugal blood pumps.Front Physiol. 2023 May 9;14:1136545. doi: 10.3389/fphys.2023.1136545. eCollection 2023. Front Physiol. 2023. PMID: 37228828 Free PMC article.
-
The Impact of Mechanical Circulatory Support Devices on White Blood Cell Phenotype and Function.Cardiovasc Eng Technol. 2025 Apr 18. doi: 10.1007/s13239-025-00784-z. Online ahead of print. Cardiovasc Eng Technol. 2025. PMID: 40251454 Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous