Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Mar 18;14(3):371-377.
doi: 10.18240/ijo.2021.03.06. eCollection 2021.

Visual quality after implantation of trifocal intraocular lenses in highly myopic eyes with different axial lengths

Affiliations

Visual quality after implantation of trifocal intraocular lenses in highly myopic eyes with different axial lengths

Hui Liu et al. Int J Ophthalmol. .

Abstract

Aim: To analyze postoperative clinical results after implantation of trifocal intraocular lenses (IOLs) in highly myopic eyes with different axial lengths (ALs).

Methods: This retrospective study describes 61 eyes of 44 patients that were implanted with trifocal diffractive IOLs (AT LISA tri 839MP). Twenty-one eyes (15 patients) were included in the AL<26 mm group, 19 eyes (13 patients) in the AL≥26 mm and <28 mm group, and 21 eyes (16 patients) in the AL≥28 mm group. Postoperative outcomes, including corrected and uncorrected distance visual acuity (UDVA), intermediate and near visual acuity at 167 cd/m2 luminance, depth of focus at 85 cd/m2 luminance, and objective optical quality parameters assessed using the Optical Quality Analysis System (OQAS), were compared among the groups at 3mo.

Results: There were no significant differences in the mean UDVA, uncorrected intermediate visual acuity, uncorrected near visual acuity, corrected distance visual acuity, distance-corrected intermediate visual acuity, and distance-corrected near visual acuity (DCNVA) among the three groups (P>0.05). Better near and intermediate visual acuity (from -1.5 D to -3.0 D) were noted on the defocus curve of the AL<26 mm group (P<0.01 vs AL≥28 mm group). Significantly higher objective scatter index (OSI) values and lower modulation transfer function (MTF) cut-off values, Strehl ratio (SR), and OQAS values (OVs) were observed in the AL≥28 mm group (P<0.01 vs AL<26 mm group). All OQAS parameters had statistically significant correlations with DCNVA and visual acuity at the vergence of -2.5 D (P<0.05 to P<0.01).

Conclusion: Implantation of trifocal IOLs provides good short-term visual and refractive outcomes in highly myopic eyes with different ALs. However, the near vision decreases in the extremely myopic eyes at lower luminance, which is associated with the lower objective optical quality in these eyes.

Keywords: OQAS; cataract; high myopia; trifocal IOL.

PubMed Disclaimer

Figures

Figure 1
Figure 1. Three-month postoperative monocular defocus curves with correction for distance
aP<0.01 compared between AL<26 mm group and AL≥28 mm group.

Similar articles

Cited by

References

    1. Wong TY, Klein BE, Klein R, Tomany SC, Lee KE. Refractive errors and incident cataracts: the Beaver Dam Eye Study. Invest Ophthalmol Vis Sci. 2001;42(7):1449–1454. - PubMed
    1. Lim R, Mitchell P, Cumming RG. Refractive associations with cataract: the Blue Mountains Eye Study. Invest Ophthalmol Vis Sci. 1999;40(12):3021–3026. - PubMed
    1. Huang Q, Huang Y, Luo Q, Fan W. Ocular biometric characteristics of cataract patients in Western China. BMC Ophthalmol. 2018;18(1):99. - PMC - PubMed
    1. Ogawa T, Shiba T, Tsuneoka H. Usefulness of implantation of diffractive multifocal intraocular lens in eyes with long axial lengths. J Ophthalmol. 2015;2015:956046. - PMC - PubMed
    1. Wang Q, Zhao G, Wang Q, Jia W. Visual quality after AcrySof IQ ReSTOR intraocular lens implantation in eyes with high myopia. Eur J Ophthalmol. 2012;22(2):168–174. - PubMed

LinkOut - more resources