Temporary changes of visual outcomes and anterior chamber parameters after phacoemulsification and low-add-power segmented intraocular lens implantation for primary angle closure disease
- PMID: 33751305
- DOI: 10.1007/s10792-021-01803-3
Temporary changes of visual outcomes and anterior chamber parameters after phacoemulsification and low-add-power segmented intraocular lens implantation for primary angle closure disease
Abstract
Purpose: To evaluate the temporary changes in visual outcomes and anterior segment parameters after cataract surgery plus low-add bifocal intraocular lens (IOL) implantation for primary angle closure disease (PACD).
Methods: This retrospective comparative case-control study included two groups: low-add-power segmented IOL and monofocal IOL. Postoperative examination involved evaluation of uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), uncorrected intermediate visual acuity (UIVA), and spherical equivalent (SE). Anterior segment examination was performed using anterior segment optical coherence tomography.
Results: This study included 19 eyes of 11 consecutive patients who underwent cataract surgery. The low-add group had better UDVA than the monofocal group at 3 months postoperatively, better UIVA at 1 month postoperatively, better UNVA at 1 week postoperatively. In the low-add group, SE increased at 1 and 3 months postoperatively compared with 1 week postoperatively. In the monofocal group, objective SE decreased at 1 and 3 months postoperatively compared with 1 week postoperatively. In the low-add group, the anterior chamber depth (ACD) became significantly deep gradually at 1 and 3 months compared with at 1 week postoperatively. In the monofocal group, the ACD became significantly shallow gradually at 1 and 3 months than at 1 week postoperatively.
Conclusion: The low-add-power segmented IOL achieved better far and intermediate distance visual acuity after cataract surgery in PACD patients than did the monofocal IOL. The ACD became deeper and SE showed a hyperopic shift with the low-add-power segmented IOL at 1 and 3 months after cataract surgery compared with at 1 week after cataract surgery.
Keywords: Anterior chamber; Cataract surgery; Hydrophilic; Low-add-power IOL; PACD.
Similar articles
-
[Visual quality comparison after multifocal toric intraocular lens or monofocal toric intraocular lens implantation].Zhonghua Yan Ke Za Zhi. 2017 Apr 11;53(4):274-280. doi: 10.3760/cma.j.issn.0412-4081.2017.04.009. Zhonghua Yan Ke Za Zhi. 2017. PMID: 28412800 Clinical Trial. Chinese.
-
Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population.BMC Ophthalmol. 2019 Aug 19;19(1):187. doi: 10.1186/s12886-019-1193-z. BMC Ophthalmol. 2019. PMID: 31426775 Free PMC article.
-
Ocular parameters associated with visual performance of enhanced monofocal intraocular lens.BMC Ophthalmol. 2024 Feb 19;24(1):74. doi: 10.1186/s12886-024-03316-w. BMC Ophthalmol. 2024. PMID: 38369454 Free PMC article.
-
Enhanced Monofocal Versus Conventional Monofocal Intraocular Lens in Cataract Surgery: A Meta-analysis.J Refract Surg. 2022 Aug;38(8):538-546. doi: 10.3928/1081597X-20220707-01. Epub 2022 Aug 1. J Refract Surg. 2022. PMID: 35947003 Review.
-
Comparison of the Clinical Performance of Refractive Rotationally Asymmetric Multifocal IOLs with Other Types of IOLs: A Meta-Analysis.J Ophthalmol. 2018 Sep 27;2018:4728258. doi: 10.1155/2018/4728258. eCollection 2018. J Ophthalmol. 2018. PMID: 30363767 Free PMC article. Review.
Cited by
-
Surgical outcome comparisons of multifocal IOLs of Lentis Comfort LS-313 MF15 and Tecnis Eyhance DIB00V.Int J Ophthalmol. 2023 Dec 18;16(12):2004-2010. doi: 10.18240/ijo.2023.12.12. eCollection 2023. Int J Ophthalmol. 2023. PMID: 38111926 Free PMC article.
References
-
- Prum BE Jr, Herndon LW Jr, Moroi SE, Mansberger SL, Stein JD, Lim MC, Rosenberg LF, Gedde SJ, Williams RD (2016) Primary angle closure preferred practice pattern((R)) guidelines. Ophthalmology 123:P1-p40. https://doi.org/10.1016/j.ophtha.2015.10.049 - DOI - PubMed
-
- (2018) [The Japan Glaucoma Society Guidelines for Glaucoma (4rd Edition)]. 107:5–49
-
- Azuara-Blanco A, Burr J, Ramsay C, Cooper D, Foster PJ, Friedman DS, Scotland G, Javanbakht M, Cochrane C, Norrie J (2016) Effectiveness of early lens extraction for the treatment of primary angle-closure glaucoma (EAGLE): a randomised controlled trial. Lancet 388:1389–1397. https://doi.org/10.1016/s0140-6736(16)30956-4 - DOI - PubMed
-
- Vu AT, Bui VA, Vu HL, Quyet D, Thai TV, Nga VT, Dinh TC, Bac ND (2019) Evaluation of anterior chamber depth and anterior chamber angle changing after phacoemulsification in the primary angle close suspect eyes. Open Access Maced J Med Sci 7:4297–4300. https://doi.org/10.3889/oamjms.2019.378 - DOI - PubMed - PMC
-
- Pedrotti E, Mastropasqua R, Bonetto J, Demasi C, Aiello F, Nucci C, Mariotti C, Marchini G (2018) Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens. Int Ophthalmol 38:1709–1716. https://doi.org/10.1007/s10792-017-0652-x - DOI - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources